Joukowsky / elastic pipe

HDPE line with extended closure

An HDPE transfer line uses an eight-second effective shutoff interval.

Inputs

Liquid and pipe
Closure and pressure
Wave speed
308.5m/s
Critical time
3.565s
Surge rise
178.4kPa
Peak pressure
6bar g
Peak within entered rating

Slow closure gives a peak at or below the rating. Transient reflections and vacuum require separate review.

Joukowsky surge envelope

Joukowsky surge envelopePeak pressure versus closure time on a compressed time scale. The dashed vertical line marks the round-trip time.0511bar g0 sCLOSURE TIME14.3 sPEAK ENVELOPEPIPE RATINGPEAK6 bar gRATING10 bar gMARGIN401.6 kPa
Peak pressure versus closure time on a compressed time scale. The dashed vertical line marks the round-trip time.

All calculated values
Elastic wave speed308.5 m/s
Round-trip time3.5652 s
Closure regimeSlow
Instantaneous Joukowsky rise400.29 kPa
Closure-adjusted surge rise178.39 kPa
Peak line pressure5.98 bar g
Remaining rating margin401.61 kPa
Rating used59.8 %
Nominal wall modulus E1 GPa
Diameter-to-wall ratio10.1

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Find the elastic wave speed308.5 m/s
  2. Compare closure with round-trip time3.5652 s
  3. Add surge to line pressure5.98 bar g

The modulus preset is a short-term value. A viscoelastic transient model can change the result for long plastic runs.

Model and limits

The elastic wall model represents one full liquid line between the valve and a reflecting boundary. Enter the effective closure time and the velocity reduction across the event. Use a consistent gauge pressure basis for initial pressure and rating.

Instantaneous closure uses the full Joukowsky rise. The slow-closure factor is a linear-closure approximation. Preset pipe moduli are nominal short-term values. Check restraint, viscoelasticity, nonlinear closure, branches, reflected waves and vapor-column separation with transient analysis. Enter the temperature-corrected rating of the weakest relevant component.

View equations and references

Worked examples