Joukowsky / elastic pipe
Partial closure with a 2 ft/s velocity change
A control valve throttles rapidly from one flowing condition to another without reaching its seat.
Inputs
Results
Edit inputs- Wave speed
- 4,377.5ft/s
- Critical time
- 0.16s
- Surge rise
- 117.7psi
- Peak pressure
- 222.7psig
Rapid closure gives a peak at or below the rating. Transient reflections and vacuum require separate review.
Joukowsky surge envelope
All calculated values
| Elastic wave speed | 4,377.5 ft/s |
|---|---|
| Round-trip time | 0.1599 s |
| Closure regime | Rapid |
| Instantaneous Joukowsky rise | 117.73 psi |
| Closure-adjusted surge rise | 117.73 psi |
| Peak line pressure | 222.73 psig |
| Remaining rating margin | 77.27 psi |
| Rating used | 74.2 % |
| Nominal wall modulus E | 29.01 Mpsi |
| Diameter-to-wall ratio | 21.7 |
Worked solution
These steps show the starting preset. The calculator above follows your edits.
- Find the elastic wave speed4,377.5 ft/s
- Compare closure with round-trip time0.1599 s
- Add surge to line pressure222.73 psig
Use the change in velocity rather than the full initial velocity. The screen adds the corresponding positive rise to operating pressure.
Model and limits
The elastic wall model represents one full liquid line between the valve and a reflecting boundary. Enter the effective closure time and the velocity reduction across the event. Use a consistent gauge pressure basis for initial pressure and rating.
Instantaneous closure uses the full Joukowsky rise. The slow-closure factor is a linear-closure approximation. Preset pipe moduli are nominal short-term values. Check restraint, viscoelasticity, nonlinear closure, branches, reflected waves and vapor-column separation with transient analysis. Enter the temperature-corrected rating of the weakest relevant component.
View equations and references