IEC 60534-8-3 screening context

Schedule 160 gas outlet attenuation

A gas control station compares heavier outlet wall with its Schedule 40 reference loss.

Inputs

Gas duty
Outlet and noise basis
Fraction of proxy flow power converted to acoustic power. Use an OEM estimate when available.
Noise at 1 m
80.2dBA
Exit Mach
0.063
Exit velocity
71.6ft/s
85 dBA margin
4.8dB
Below screening references

The estimated 1 m level is below 85 dBA and exit Mach is within 0.30.

Exit Mach and acoustic margin

Exit Mach and acoustic marginThe 85 dBA mark is an exposure-screening reference. Use a measured 8-hour time-weighted average for OSHA assessment.LEVEL AT 1 M80.2 dBAEXIT MACH0.06385 dBA45 dBA125 dBAA-WEIGHTED SCREENESTIMATE80.2 dBAACTION REF.85 dBA85 dBA MARGIN4.8 dB
The 85 dBA mark is an exposure-screening reference. Use a measured 8-hour time-weighted average for OSHA assessment.

All calculated values
External sound level at 1 m80.2 dBA
Margin to 85 dBA reference4.8 dB
Outlet-pipe Mach number0.0626
Trim velocity screenStandard screen
Outlet velocity71.58 ft/s
Local speed of sound1,144.09 ft/s
Ideal-gas outlet density0.357 lb/ft³
Absolute pressure ratio P₂ / P₁0.5538
Outlet pipe ID5.187 in
Outlet wall thickness0.719 in
Estimated transmission loss38.2 dB
Available flow-power proxy87,248.53 W
Estimated source acoustic power8.725 W

Worked solution

These steps show the starting preset. The calculator above follows your edits.

  1. Calculate outlet Mach0.0626
  2. Estimate external noise at 1 m80.2 dBA
  3. Compare with the 85 dBA reference4.8 dB

Additional wall can improve this simple attenuation estimate while reducing inside diameter. Check both acoustic margin and exit Mach.

Model and limits

The gas-only estimate uses dry, single-phase ideal-gas density at outlet pressure and temperature, nominal outlet ID and a user-entered acoustic efficiency. The 1 m sound level is a free-field power proxy with a user-entered A-weighting offset.

The full IEC model requires OEM data and frequency-dependent transmission. The schedule correction here is a relative mass-law estimate. Mach above 0.30 prompts an exit velocity and low-noise trim review. Mach of 1 or higher indicates the simplified outlet model has exceeded its useful range. The 85 dBA OSHA hearing conservation action level is an 8-hour TWA. The margin to a 1 m estimate is a screening comparison.

View equations and references

Worked examples