ACI 318-19 §19.2 / §24.2

Lightweight concrete deflection

A lightweight section uses its entered density to calculate Ec and a reduced rupture modulus.

Edit inputs ↓

Inputs

Editable example

Section
Service load & duration
Gross Ig 5.75e+9mm⁴
Cracked Icr 3.10e+9mm⁴
Effective Ie 3.21e+9mm⁴
Long-term Δ 12.718mm
AnatomyDiagrammatic scale
Parameter-linked deflection drawing. Diagrammatic scale. TRANSFORMED SECTIONRELATIVE STIFFNESSIgIcrIekd 196.09 mmℓ 6.1 mΔ 12.718 mm

Screening

Within screening limits
Governing deflection utilization50.1%
Bischoff cracked stiffness49.9% below the threshold
  • Immediate live-load incrementΔlive ≤ ℓ/360
    Within limit
  • Total with sustained-load creepΔtotal ≤ ℓ/240 (screening threshold)
    Within limit

Approximate midspan deflection for prismatic, simply supported members under a uniform load. Limits ℓ/360 for incremental live load and ℓ/240 for total deflection are screening thresholds. Attachment timing and the applicable code limit need project-specific review.

Calculation readout
QuantityValue
Gross concrete inertia Ig5.75e+9 mm⁴
Cracked transformed inertia Icr3.10e+9 mm⁴
Effective total-service inertia Ie3.21e+9 mm⁴
Total long-term deflection12.718 mm
Cracked neutral axis kd196.088 mm
Gross centroid from top304.8 mm
Concrete modulus Ec16,601.7 MPa
Modular ratio n12.044
Modulus of rupture fr2.45 MPa
Cracking moment Mcr46.3 kN·m
Effective cracking threshold30.87 kN·m
Effective sustained inertia3.51e+9 mm⁴
Total immediate deflection8.382 mm
Sustained immediate deflection4.047 mm
Immediate live increment4.335 mm
Additional creep and shrinkage4.336 mm
Instantaneous live limit ℓ/36016.933 mm
Total screening limit ℓ/24025.4 mm
Time multiplier λΔ1.071

Original example

Worked solution

Default calculator ↗

Starting inputs

Lightweight factor λ
0.75
Concrete unit weight
1,762.031 kg/m³
Sustained moment Ms
61.012 kN·m
Added live moment Ml
54.233 kN·m
Sustained duration
6 months (ξ = 1.2)

Calculated result

Gross concrete inertia Ig
5.75e+9 mm⁴
Cracked transformed inertia Icr
3.10e+9 mm⁴
Effective total-service inertia Ie
3.21e+9 mm⁴
Total long-term deflection
12.718 mm

Both n and the cracking threshold change with lightweight concrete. Read the bias in Ie and the resulting service deflection.

Preset screening · Bischoff cracked stiffness · Within limits

How the check works

Code basis ↗
  1. Use Ec = 57,000√f′c for normalweight concrete, or 33wc^1.5√f′c with the entered lightweight density. Use Es = 29,000 ksi and n = Es/Ec. Find cracked neutral axis and Icr with equivalent concrete area and no tensile concrete.
  2. Set Mcr = 7.5λ√f′c Ig/yt. Below two-thirds Mcr use Ig; above it interpolate with the squared Bischoff expression in Table 24.2.3.5. Calculate separate stiffnesses at sustained and total moment.
  3. Use Δi = 5 Ma ℓ²/(48 Ec Ie). The live increment is Δtotal,imm − Δsust,imm. Add ξ/(1 + 50ρ′) × Δsust,imm to total immediate deflection.