Inputs
Editable example
Screening
Within screening limits- Immediate live-load incrementΔlive ≤ ℓ/360Within limit
- Total with sustained-load creepΔtotal ≤ ℓ/240 (screening threshold)Within limit
Approximate midspan deflection for prismatic, simply supported members under a uniform load. Limits ℓ/360 for incremental live load and ℓ/240 for total deflection are screening thresholds. Attachment timing and the applicable code limit need project-specific review.
Calculation readout
| Quantity | Value |
|---|---|
| Gross concrete inertia Ig | 5.75e+9 mm⁴ |
| Cracked transformed inertia Icr | 3.10e+9 mm⁴ |
| Effective total-service inertia Ie | 3.21e+9 mm⁴ |
| Total long-term deflection | 12.718 mm |
| Cracked neutral axis kd | 196.088 mm |
| Gross centroid from top | 304.8 mm |
| Concrete modulus Ec | 16,601.7 MPa |
| Modular ratio n | 12.044 |
| Modulus of rupture fr | 2.45 MPa |
| Cracking moment Mcr | 46.3 kN·m |
| Effective cracking threshold | 30.87 kN·m |
| Effective sustained inertia | 3.51e+9 mm⁴ |
| Total immediate deflection | 8.382 mm |
| Sustained immediate deflection | 4.047 mm |
| Immediate live increment | 4.335 mm |
| Additional creep and shrinkage | 4.336 mm |
| Instantaneous live limit ℓ/360 | 16.933 mm |
| Total screening limit ℓ/240 | 25.4 mm |
| Time multiplier λΔ | 1.071 |