Normalweight, solid nonprestressed slabs. The thickness shortcut assumes no damage-sensitive attachments. Check load combinations, one-way shear, anchorage and the crack-control spacing of §24.3 separately.
Apply ℓ/20, ℓ/24, ℓ/28 or ℓ/10 and the factor (0.4 + fy/100,000). A thinner slab requires a calculated deflection check.
Find d from h, clear cover and half of the bar diameter. Calculate Aₛ per unit width and the tension-controlled φMn using the same strain-compatible rectangular block as the beam tool.
ACI 318-19 §§7.6.1.1 and 24.4.3.2 use 0.0018Ag for flexure and deformed T&S steel. Use the ACI 318-19 minimum for screening. Check upper spacing of min(3h, 18 in) for flexure and min(5h, 18 in) for T&S. Clear spacing must also reach max(1 in, db); verify the aggregate-size term separately.
Solid slab · unit-width strip · Further analysis required
Inputs
Clear span ℓ
5.486 m
Support condition
One end continuous
Slab thickness h
241.3 mm
Clear flexural cover
19.05 mm
Concrete strength f′c
27.579 MPa
Steel yield strength fy
551.581 MPa
Factored strip moment Mu
40.034 kN·m/m
Flexural bar size
No. 16 (US #5)
Flexural bar spacing
203.2 mm
Transverse bar size
No. 16 (US #5)
T&S bar spacing
304.8 mm
Calculated values
Strip design moment φMn
99.06 kN·m/m
Minimum slab thickness
274.32 mm
ACI minimum strip steel
434.34 mm²/m
Maximum flexural spacing
457.2 mm
Effective depth d
214.313 mm
Provided flexural steel
984.25 mm²/m
Provided transverse T&S steel
656.167 mm²/m
Maximum T&S spacing
457.2 mm
Grade-scaled reference (legacy)
337.82 mm²/m
Net tensile strain εt
20,598 με
Strength factor φ
0.9
Screening
Tension controlled · Strip moment utilization 40.4%
Flexural strength · Within limit
Tension control · Within limit
Minimum strip reinforcement · Within limit
Minimum clear bar spacing · Within limit
Maximum bar spacing · Within limit
Minimum thickness · Review
Normalweight, solid nonprestressed slabs. The thickness shortcut assumes no damage-sensitive attachments. Check load combinations, one-way shear, anchorage and the crack-control spacing of §24.3 separately.