ACI 318-19 §7.3 / §7.6 / §24.4

Slab bars beyond the spacing limit

Larger bars supply area, but wide spacing makes the strip detailing screen fail.

Edit inputs ↓

Inputs

Editable example

Slab & demand
Bar layout
φMn / strip 7.94kip·ft/ft
Thickness min 7.2in
Steel min 0.173in²/ft
Flex spacing 18in
AnatomyDiagrammatic scale
Parameter-linked slab drawing. Diagrammatic scale. SIMPLE SPANhℓ 12 ftd 6.88 ins 20 in

Screening

Limit exceeded
Strip moment utilization75.6%
Tension controlled24.4% below the threshold
  • Flexural strengthMu ≤ φMn for the design strip
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §7.3.3.1
    Within limit
  • Minimum strip reinforcementFlexural and transverse T&S steel each ≥ 0.0018Ag
    Within limit
  • Minimum clear bar spacingClear spacing ≥ max(1 in, db); check aggregate size separately
    Within limit
  • Maximum bar spacingFlexural and T&S bar spacing within upper limits
    Outside limit
  • Minimum thicknessh meets the span-to-depth shortcut
    Within limit

Normalweight, solid nonprestressed slabs. The thickness shortcut assumes no damage-sensitive attachments. Check load combinations, one-way shear, anchorage and the crack-control spacing of §24.3 separately.

Calculation readout
QuantityValue
Strip design moment φMn7.94 kip·ft/ft
Minimum slab thickness7.2 in
ACI minimum strip steel0.173 in²/ft
Maximum flexural spacing18 in
Effective depth d6.875 in
Provided flexural steel0.264 in²/ft
Provided transverse T&S steel0.186 in²/ft
Maximum T&S spacing18 in
Grade-scaled reference (legacy)0.173 in²/ft
Net tensile strain εt42,156 με
Strength factor φ0.9

Original example

Worked solution

Default calculator ↗

Starting inputs

Factored strip moment Mu
6 kip·ft/ft
Flexural bar size
#6
Flexural bar spacing
20 in
Transverse bar size
#5
T&S bar spacing
20 in

Calculated result

Strip design moment φMn
7.94 kip·ft/ft
Minimum slab thickness
7.2 in
ACI minimum strip steel
0.173 in²/ft
Maximum flexural spacing
18 in

Compare the spacing limit separately from bar area. Increasing bar size does not remove the spacing check.

Preset screening · Tension controlled · Limit exceeded

How the check works

Code basis ↗
  1. Apply ℓ/20, ℓ/24, ℓ/28 or ℓ/10 and the factor (0.4 + fy/100,000). A thinner slab requires a calculated deflection check.
  2. Find d from h, clear cover and half of the bar diameter. Calculate Aₛ per unit width and the tension-controlled φMn using the same strain-compatible rectangular block as the beam tool.
  3. ACI 318-19 §§7.6.1.1 and 24.4.3.2 use 0.0018Ag for flexure and deformed T&S steel. Use the ACI 318-19 minimum for screening. Check upper spacing of min(3h, 18 in) for flexure and min(5h, 18 in) for T&S. Clear spacing must also reach max(1 in, db); verify the aggregate-size term separately.