ACI 318-19 §7.3 / §7.6 / §24.4

High-grade slab below the ACI T&S minimum

Grade 100 bars provide a comparison between the legacy scaled reference and the current fixed steel ratio.

Edit inputs ↓

Inputs

Editable example

Slab & demand
Bar layout
φMn / strip 20.35kip·ft/ft
Thickness min 8.4in
Steel min 0.205in²/ft
Flex spacing 18in
AnatomyDiagrammatic scale
Parameter-linked slab drawing. Diagrammatic scale. SIMPLE SPANhℓ 10 ftd 8.44 ins 11 in

Screening

Limit exceeded
Strip moment utilization34.4%
Tension controlled65.6% below the threshold
  • Flexural strengthMu ≤ φMn for the design strip
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §7.3.3.1
    Within limit
  • Minimum strip reinforcementFlexural and transverse T&S steel each ≥ 0.0018Ag
    Outside limit
  • Minimum clear bar spacingClear spacing ≥ max(1 in, db); check aggregate size separately
    Within limit
  • Maximum bar spacingFlexural and T&S bar spacing within upper limits
    Within limit
  • Minimum thicknessh meets the span-to-depth shortcut
    Within limit

Normalweight, solid nonprestressed slabs. The thickness shortcut assumes no damage-sensitive attachments. Check load combinations, one-way shear, anchorage and the crack-control spacing of §24.3 separately.

Calculation readout
QuantityValue
Strip design moment φMn20.35 kip·ft/ft
Minimum slab thickness8.4 in
ACI minimum strip steel0.205 in²/ft
Maximum flexural spacing18 in
Effective depth d8.438 in
Provided flexural steel0.338 in²/ft
Provided transverse T&S steel0.171 in²/ft
Maximum T&S spacing18 in
Grade-scaled reference (legacy)0.16 in²/ft
Net tensile strain εt22,958 με
Strength factor φ0.9

Original example

Worked solution

Default calculator ↗

Starting inputs

Clear span ℓ
10 ft
Slab thickness h
9.5 in
Steel yield strength fy
100 ksi
Factored strip moment Mu
7 kip·ft/ft
Flexural bar spacing
11 in
T&S bar spacing
14 in

Calculated result

Strip design moment φMn
20.35 kip·ft/ft
Minimum slab thickness
8.4 in
ACI minimum strip steel
0.205 in²/ft
Maximum flexural spacing
18 in

Use 0.0018Ag for the design check. The lower grade-scaled value shown in the readout is a comparison only.

Preset screening · Tension controlled · Limit exceeded

How the check works

Code basis ↗
  1. Apply ℓ/20, ℓ/24, ℓ/28 or ℓ/10 and the factor (0.4 + fy/100,000). A thinner slab requires a calculated deflection check.
  2. Find d from h, clear cover and half of the bar diameter. Calculate Aₛ per unit width and the tension-controlled φMn using the same strain-compatible rectangular block as the beam tool.
  3. ACI 318-19 §§7.6.1.1 and 24.4.3.2 use 0.0018Ag for flexure and deformed T&S steel. Use the ACI 318-19 minimum for screening. Check upper spacing of min(3h, 18 in) for flexure and min(5h, 18 in) for T&S. Clear spacing must also reach max(1 in, db); verify the aggregate-size term separately.