ACI 318-19 §7.3 / §7.6 / §24.4

Grade 80 slab with one end continuous

A 9.5 in slab uses Grade 80 bars and is screened against the modified depth shortcut.

Edit inputs ↓

Inputs

Editable example

Slab & demand
Bar layout
φMn / strip 99.06kN·m/m
Thickness min 274.32mm
Steel min 434.34mm²/m
Flex spacing 457.2mm
AnatomyDiagrammatic scale
Parameter-linked slab drawing. Diagrammatic scale. ONE END CONTINUOUShℓ 5.49 md 214.31 mms 203.2 mm

Screening

Further analysis required
Strip moment utilization40.4%
Tension controlled59.6% below the threshold
  • Flexural strengthMu ≤ φMn for the design strip
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §7.3.3.1
    Within limit
  • Minimum strip reinforcementFlexural and transverse T&S steel each ≥ 0.0018Ag
    Within limit
  • Minimum clear bar spacingClear spacing ≥ max(1 in, db); check aggregate size separately
    Within limit
  • Maximum bar spacingFlexural and T&S bar spacing within upper limits
    Within limit
  • Minimum thicknessCalculated deflection check required
    Review

Normalweight, solid nonprestressed slabs. The thickness shortcut assumes no damage-sensitive attachments. Check load combinations, one-way shear, anchorage and the crack-control spacing of §24.3 separately.

Calculation readout
QuantityValue
Strip design moment φMn99.06 kN·m/m
Minimum slab thickness274.32 mm
ACI minimum strip steel434.34 mm²/m
Maximum flexural spacing457.2 mm
Effective depth d214.313 mm
Provided flexural steel984.25 mm²/m
Provided transverse T&S steel656.167 mm²/m
Maximum T&S spacing457.2 mm
Grade-scaled reference (legacy)337.82 mm²/m
Net tensile strain εt20,598 με
Strength factor φ0.9

Original example

Worked solution

Default calculator ↗

Starting inputs

Clear span ℓ
5.486 m
Support condition
One end continuous
Slab thickness h
241.3 mm
Steel yield strength fy
551.581 MPa
Factored strip moment Mu
40.034 kN·m/m
Flexural bar spacing
203.2 mm
Transverse bar size
No. 16 (US #5)

Calculated result

Strip design moment φMn
99.06 kN·m/m
Minimum slab thickness
274.32 mm
ACI minimum strip steel
434.34 mm²/m
Maximum flexural spacing
457.2 mm

Multiply ℓ/24 by the steel grade factor. A shallow result calls for a calculated deflection check.

Preset screening · Tension controlled · Further analysis required

How the check works

Code basis ↗
  1. Apply ℓ/20, ℓ/24, ℓ/28 or ℓ/10 and the factor (0.4 + fy/100,000). A thinner slab requires a calculated deflection check.
  2. Find d from h, clear cover and half of the bar diameter. Calculate Aₛ per unit width and the tension-controlled φMn using the same strain-compatible rectangular block as the beam tool.
  3. ACI 318-19 §§7.6.1.1 and 24.4.3.2 use 0.0018Ag for flexure and deformed T&S steel. Use the ACI 318-19 minimum for screening. Check upper spacing of min(3h, 18 in) for flexure and min(5h, 18 in) for T&S. Clear spacing must also reach max(1 in, db); verify the aggregate-size term separately.