ACI 318-19 §19.2 / §24.2

Live load crosses the cracking threshold

The sustained case is below the cracking threshold, while sustained plus live load is above it.

Edit inputs ↓

Inputs

Editable example

Section
Service load & duration
Gross Ig 13,824in⁴
Cracked Icr 5,455.8in⁴
Effective Ie 8,376.5in⁴
Long-term Δ 0.131in
AnatomyDiagrammatic scale
Parameter-linked deflection drawing. Diagrammatic scale. TRANSFORMED SECTIONRELATIVE STIFFNESSIgIcrIekd 6.65 inℓ 20 ftΔ 0.131 in

Screening

Within screening limits
Governing deflection utilization13.1%
Bischoff cracked stiffness86.9% below the threshold
  • Immediate live-load incrementΔlive ≤ ℓ/360
    Within limit
  • Total with sustained-load creepΔtotal ≤ ℓ/240 (screening threshold)
    Within limit

Approximate midspan deflection for prismatic, simply supported members under a uniform load. Limits ℓ/360 for incremental live load and ℓ/240 for total deflection are screening thresholds. Attachment timing and the applicable code limit need project-specific review.

Calculation readout
QuantityValue
Gross concrete inertia Ig13,824 in⁴
Cracked transformed inertia Icr5,455.8 in⁴
Effective total-service inertia Ie8,376.5 in⁴
Total long-term deflection0.131 in
Cracked neutral axis kd6.647 in
Gross centroid from top12 in
Concrete modulus Ec3,605 ksi
Modular ratio n8.044
Modulus of rupture fr474.34 psi
Cracking moment Mcr45.54 kip·ft
Effective cracking threshold30.36 kip·ft
Effective sustained inertia13,824 in⁴
Total immediate deflection0.095 in
Sustained immediate deflection0.029 in
Immediate live increment0.066 in
Additional creep and shrinkage0.036 in
Instantaneous live limit ℓ/3600.667 in
Total screening limit ℓ/2401 in
Time multiplier λΔ1.25

Original example

Worked solution

Default calculator ↗

Starting inputs

Sustained moment Ms
20 kip·ft
Added live moment Ml
20 kip·ft
Sustained duration
12 months (ξ = 1.4)

Calculated result

Gross concrete inertia Ig
13,824 in⁴
Cracked transformed inertia Icr
5,455.8 in⁴
Effective total-service inertia Ie
8,376.5 in⁴
Total long-term deflection
0.131 in

Calculate the live deflection increment by subtraction. This includes the stiffness change as the section crosses the cracking threshold.

Preset screening · Bischoff cracked stiffness · Within limits

How the check works

Code basis ↗
  1. Use Ec = 57,000√f′c for normalweight concrete, or 33wc^1.5√f′c with the entered lightweight density. Use Es = 29,000 ksi and n = Es/Ec. Find cracked neutral axis and Icr with equivalent concrete area and no tensile concrete.
  2. Set Mcr = 7.5λ√f′c Ig/yt. Below two-thirds Mcr use Ig; above it interpolate with the squared Bischoff expression in Table 24.2.3.5. Calculate separate stiffnesses at sustained and total moment.
  3. Use Δi = 5 Ma ℓ²/(48 Ec Ie). The live increment is Δtotal,imm − Δsust,imm. Add ξ/(1 + 50ρ′) × Δsust,imm to total immediate deflection.