ACI 318-19 §16.3 / §21.2 / §22.8

Shallow support limits the projected area

Wide support edges are available, but a shallow projection depth limits confinement.

Edit inputs ↓

Inputs

Editable example

Contact & support
Interface steel
φBn 424.32kip
Area A₂ 256in²
Confinement 1.333 
Excess Pu 0kip
AnatomyDiagrammatic scale
Parameter-linked bearing drawing. Diagrammatic scale. SUPPORT SECTIONPROJECTED PLAN1V : 2H projectionA₁ 144 in²A₂ 256 in²× 1.333

Screening

Within screening limits
Bearing utilization94.3%
Confined bearing5.7% below the threshold
  • Projection geometryA₂ fits within the 1V:2H envelope
    Within limit
  • Concrete bearing strengthPu ≤ φBn
    Within limit
  • Interface reinforcementDowel or continuous steel area ≥ 0.005Ag
    Within limit

Concentric compression on a rectangular support with uniform depth. Check the loaded member side, eccentricity, punching, dowel development, shear friction and actual reinforcement load transfer separately.

Calculation readout
QuantityValue
Design bearing φBn424.32 kip
Supporting area A₂ used256 in²
Confinement multiplier1.333
Demand beyond concrete bearing0 kip
Loaded area A₁144 in²
Maximum projected area A₂256 in²
Permitted side projection2 in
Nominal bearing Bn652.8 kip
Supported gross area Ag144 in²
Minimum interface steel0.72 in²
Provided interface steel1.24 in²

Original example

Worked solution

Default calculator ↗

Starting inputs

Support width
30 in
Support length
30 in
Available projection depth
1 in
Factored compression Pu
400 kip

Calculated result

Design bearing φBn
424.32 kip
Supporting area A₂ used
256 in²
Confinement multiplier
1.333
Demand beyond concrete bearing
0 kip

At 1V:2H a 1 in depth permits 2 in spread on each side. Use that footprint instead of the full support plan.

Preset screening · Confined bearing · Within limits

How the check works

Code basis ↗
  1. Take A₁ as loaded width × length. At 1V:2H the uniform side projection is limited by 2 × depth and the nearest support edge. The resulting footprint bounds A₂.
  2. Use φBn = 0.65 × 0.85f′c A₁ × min(√(A₂/A₁), 2). Confinement requires support beyond all loaded edges. Report any Pu above φBn as force requiring a separately designed transfer path.