ACI 318-19

Calculation methodology

The code provisions, design assumptions and limits behind each sheet.

Units and interpretation

Equations use the inch-pound edition of ACI 318-19. SI display converts inputs and results. ASTM bar designations in SI show the paired US number, such as No. 10 (US #3). Both unit modes use the same nominal bar section. Slab strip results are reported per foot or per meter of width.

Factored loads belong in strength sheets. Unfactored service moments belong in the deflection sheet. Utilization compares the named demand to the corresponding capacity or limit, while each sheet lists its additional checks. A licensed design professional must verify assumptions, code adoption, design loads, detailing and the complete structure.

§9.3 / §9.6 / §22.2

Concrete Beam Flexure

  1. β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
  2. Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
  3. Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).

Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.

§9.6 / §9.7 / §22.5

Concrete Beam One-Way Shear

  1. Use Table 22.5.5.1(a) when Av reaches Av,min. Below Av,min, use (c) with λs and ρw = As/(bw d). Cap the axial compression stress term at 0.05f′c and floor Vc at zero. Limit √f′c to 100 for the concrete term unless minimum web steel is present.
  2. Take Vs = Av fyt d/s, limiting fyt to 60 ksi for deformed-bar stirrups. Calculate φVn with φ = 0.75 and cap the credited Vs at 8√f′c bw d. Check the required Vs against that section limit.
  3. Use max(0.75√f′c, 50)bw s/fyt for Av,min and apply the ordinary-beam trigger Vu > φλ√f′c bw d. Select the spacing band from required Vs per Table 9.7.6.2.2: min(d/2, 24 in) up to 4√f′c bw d, then min(d/4, 12 in).

Ordinary deformed-bar stirrups under nonseismic action. Check leg spacing across the web, end anchorage and torsion separately.

§6.2 / §10.6 / §22.4

Concrete Column Axial Capacity

  1. Compute Ag and P₀ = 0.85f′c(Ag − Ast) + fy Ast with fy limited to 80 ksi. Limit Pn to 0.80P₀ with φ = 0.65 for ties, or 0.85P₀ with φ = 0.75 for spirals.
  2. Screen 1–8% gross reinforcement. Use r = √(Ig/Ag) about the weak axis, then compare k lu/r with the threshold in §6.2.5.1.
  3. Enter M1/M2 as positive for single curvature and negative for double curvature. This is the reverse of the sign in §6.2.5.1, so the braced expression here is min(40, 34 − 12 M1/M2). The unbraced limit is 22.

The axial ceiling is one point on a column interaction diagram. Check actual eccentricity and P–M strength, reinforcement detailing and any second-order effects before using the section.

§8.7 / §22.6

Slab & Footing Punching Shear

  1. Measure bo at d/2 with the column faces flush at modeled free edges. Use the lesser of the three stress equations in Table 22.6.5.2, with βc = long side/short side, αs = 40/30/20 and √f′c limited to 100.
  2. For headed studs, use Table 22.6.6.1 for inner concrete stress and add Vs = Av fyt d/s. Use the actual √f′c for the Table 22.6.6.3 inner ceiling and Table 8.7.7.1.2 spacing threshold. Apply the 100 psi root cap to concrete stress, including 2λsλ√f′c at the supplied outer perimeter.
  3. Apply the full entered net shear to both sections as a conservative outer-perimeter screen. Check Av/s ≥ 2√f′c bo/fyt with actual √f′c per §22.6.8.3 and check the first-row, radial and tangential spacing limits.

Direct shear only. Supply net Vu at the section. Check unbalanced moment, openings, slab edge offsets, the actual perimeter geometry and local slab flexural steel per §8.6.1.2. For studs, provide the shortest enclosing outer perimeter and verify head, rail and cover detailing.

§25.3 / §25.4 / §25.5

Rebar Development & Lap Splice

  1. Use cᵦ = min(clear cover + db/2, bar spacing/2). Cap (cᵦ + Ktr)/db at 2.5, ψtψe at 1.7 and √f′c at 100. Calculate ℓd from Eq. (25.4.2.4a) with a 12 in floor.
  2. Check a Class B splice with the §25.5.2 minimum: multiply the unfloored ℓd by 1.3 and then apply the 12 in floor. The detail readout also shows 1.3 times the floored straight length for comparison.
  3. Use Eq. (25.4.3.1) and its own hook factors for ℓdh, subject to 8db and 6 in minima. A 90° hook needs a 12db tail; a 180° hook needs max(4db, 2.5 in). Check the outer bend envelope and tail run.

Ordinary nonseismic tension details. Available length is measured along the straight bar or to the outside of the hook. Check minimum cover, bend fabrication and confinement at discontinuous ends separately.

§7.3 / §7.6 / §24.4

One-Way Slab Flexure & Thickness

  1. Apply ℓ/20, ℓ/24, ℓ/28 or ℓ/10 and the factor (0.4 + fy/100,000). A thinner slab requires a calculated deflection check.
  2. Find d from h, clear cover and half of the bar diameter. Calculate Aₛ per unit width and the tension-controlled φMn using the same strain-compatible rectangular block as the beam tool.
  3. ACI 318-19 §§7.6.1.1 and 24.4.3.2 use 0.0018Ag for flexure and deformed T&S steel. Use the ACI 318-19 minimum for screening. Check upper spacing of min(3h, 18 in) for flexure and min(5h, 18 in) for T&S. Clear spacing must also reach max(1 in, db); verify the aggregate-size term separately.

Normalweight, solid nonprestressed slabs. The thickness shortcut assumes no damage-sensitive attachments. Check load combinations, one-way shear, anchorage and the crack-control spacing of §24.3 separately.

§19.2 / §24.2

Cracked Section & Beam Deflection

  1. Use Ec = 57,000√f′c for normalweight concrete, or 33wc^1.5√f′c with the entered lightweight density. Use Es = 29,000 ksi and n = Es/Ec. Find cracked neutral axis and Icr with equivalent concrete area and no tensile concrete.
  2. Set Mcr = 7.5λ√f′c Ig/yt. Below two-thirds Mcr use Ig; above it interpolate with the squared Bischoff expression in Table 24.2.3.5. Calculate separate stiffnesses at sustained and total moment.
  3. Use Δi = 5 Ma ℓ²/(48 Ec Ie). The live increment is Δtotal,imm − Δsust,imm. Add ξ/(1 + 50ρ′) × Δsust,imm to total immediate deflection.

Approximate midspan deflection for prismatic, simply supported members under a uniform load. Limits ℓ/360 for incremental live load and ℓ/240 for total deflection are screening thresholds. Attachment timing and the applicable code limit need project-specific review.

§16.3 / §21.2 / §22.8

Concrete Pedestal Bearing & Dowels

  1. Take A₁ as loaded width × length. At 1V:2H the uniform side projection is limited by 2 × depth and the nearest support edge. The resulting footprint bounds A₂.
  2. Use φBn = 0.65 × 0.85f′c A₁ × min(√(A₂/A₁), 2). Confinement requires support beyond all loaded edges. Report any Pu above φBn as force requiring a separately designed transfer path.
  3. For a cast-in-place column or pedestal to foundation, compare the provided interface steel with 0.005 times supported gross area. A₁ is the default when it represents the gross area of the supported member.

Concentric compression on a rectangular support with uniform depth. Check the loaded member side, eccentricity, punching, dowel development, shear friction and actual reinforcement load transfer separately.

References