ACI 318-19 §9.3 / §9.6 / §22.2

Concrete Beam Flexure Calculator

Find the Whitney stress block, tensile strain and design moment for singly or doubly reinforced rectangular beams.

Edit inputs ↓

Inputs

Rectangular section · pure bending

Section
Reinforcement & demand
φMn 210.71kip·ft
Block a 3.49in
Axis c 4.1in
Strain εt 12,730με
AnatomyDiagrammatic scale
Parameter-linked flexure drawing. Diagrammatic scale. RC SECTIONSTRAINWHITNEY BLOCKhb 12 ind 21.5 ina 3.49 in

Screening

Within screening limits
Moment utilization85.4%
Tension controlled14.6% below the threshold
  • Bending strengthMu ≤ φMn
    Within limit
  • Minimum tension steelAs ≥ As,min per §9.6.1.2
    Within limit
  • Tension controlεt ≥ εty + 0.003 per §9.3.3.1
    Within limit

Positive pure bending of a nonprestressed rectangular beam. The calculation excludes combined axial force, shear, anchorage and the minimum-steel exception in §9.6.1.3.

Calculation readout
QuantityValue
Design moment φMn210.71 kip·ft
Stress block depth a3.49 in
Neutral axis depth c4.1 in
Net tensile strain εt12,730 με
Strength factor φ0.9
Whitney factor β₁0.85
Tension-controlled limit5,069 με
Nominal moment Mn234.12 kip·ft
Minimum tension steel As,min0.86 in²
Concrete compression Cc142.2 kip
Top steel force Cs,net0 kip
Tension steel force Ts142.2 kip

How the check works

Code basis ↗
  1. β₁ drops linearly from 0.85 at 4,000 psi by 0.05 per additional 1,000 psi, with a 0.65 floor at 8,000 psi. The two strength thresholds display as approximately 27.6 and 55.2 MPa.
  2. Solve force equilibrium using εcu = 0.003, a = β₁c and elastic-perfectly plastic steel. Deduct 0.85f′c from the stress of top steel inside the concrete block. Sum moments of the compression forces about the tension steel.
  3. Use φ = 0.65 below εty and interpolate to 0.90 at εty + 0.003, with εty = fy/Es. Check tension control and As,min = max(3√f′c, 200)bw d / min(fy, 80 ksi).