0.5 dB Mismatch Loss to Maximum VSWR
Convert a 0.5 dB mismatch-loss budget into maximum VSWR, accepted power and return loss for an RF interface.
Results
Preset estimate- Reflection coefficient |Γ|
- 0.32977
- Return loss
- 9.636 dB
- Mismatch loss
- 0.5 dB
Single-port power
- Accepted power
- 89.1251 %
- Reflected power
- 10.8749 %
Worked example
A 0.5 dB budget retains about 89.13% of incident power at the load. Its complement is the reflected fraction. Use the calculator’s VSWR and return-loss values as alternative forms of that same budget.
If a specification allocates loss across several interfaces, measure the combined assembly when phase matters. This conversion describes one reflection plane with a matched source.
- Voltage standing wave ratio
- 1.984 :1
- Reflection coefficient |Γ|
- 0.32977
- Return loss
- 9.636 dB
- Mismatch loss
- 0.5 dB
Formulas & assumptions
- |Γ| = (VSWR − 1)/(VSWR + 1). VSWR = (1 + |Γ|)/(1 − |Γ|).
- Return loss = −20 log₁₀|Γ|. Mismatch loss = −10 log₁₀(1 − |Γ|²).
- Reflected power = 100 × |Γ|² percent. Accepted power = 100 × (1 − |Γ|²) percent.
Use the measurement at the antenna or load reference plane. A lossy feed can make return loss look better at the radio end. A VNA’s log-magnitude S₁₁ usually uses the opposite sign from positive return loss.
Accepted power can become radiation or heat. This single-port converter does not determine antenna efficiency or the phase of the reflection.
Questions & answers
Is a 0.5 dB mismatch allocation close to a 2:1 VSWR?
Yes. 0.5 dB corresponds to about 1.98:1. An exact 2:1 match costs about 0.512 dB.
How do I back out reflection from a mismatch loss requirement?
Convert mismatch loss to the accepted fraction with 10^(−loss/10). Subtract from one for reflected power, then take the square root for |Γ|.