Coax Cable Loss & Attenuation Calculator

See how much signal reaches the antenna and which coax types leave more power at the far end.

Jump to results ↓

Inputs

Cable & installation
Measure at the load and use the line’s reference impedance.
Transmit power & gain

Results

Preset estimate
Matched cable loss 1.97dB

LMR-400 · 50 Ω reference

Total feed loss
2.45 dB
At antenna input
17.55 dBm
EIRP
20.55 dBm
Matched coax loss comparisonMATCHED LOSS915 MHzRG-586.89 dBRG-17415.9 dBRG-2133.76 dBLMR-1955 dBLMR-2403.81 dBLMR-4001.97 dBLMR-6001.26 dBRG-62.97 dB
One-way cable loss at the same length and frequency for all eight models.

Feed loss & radiated power

Matched attenuation
3.94 dB / 100 ft
Matched attenuation, metric
12.92 dB / 100 m
Cable and connector loss
2.27 dB
Power at matched feed end
17.73 dBm
Additional load mismatch loss
0.18 dB
Conducted input reaching antenna
56.94 %
ERP
18.4 dBm
Data model
LMR-400 · catalog coefficients

Worked example

See how much signal reaches the antenna and which coax types leave more power at the far end.

Matched cable loss
1.97 dB
Total feed loss
2.45 dB
At antenna input
17.55 dBm
EIRP
20.55 dBm

Formulas & assumptions

  • Matched attenuation (dB/100 ft) = k₁√fMHz + k₂fMHz. Scale by one-way length divided by 100 ft.
  • |Γ| = (VSWR − 1)/(VSWR + 1). Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Total loss = matched cable loss + connector loss + mismatch loss. EIRP = TX dBm − total loss + antenna dBi. ERP = EIRP − 2.15 dB.

The LMR curves use Times Microwave coefficients at nominal conditions. RG curves fit the named Belden parts, so other constructions can differ. Comparisons mark frequencies above the published RG data as extrapolated.

Enter one load mismatch with a matched source. Multiple reflection phase, connector variation, cable temperature and wet or damaged assemblies require measured data.

References

Questions & answers

Does the coax calculator need the round-trip cable length?

Enter the one-way physical feed length. A round-trip correction applies to a reflected wave in a measurement, while transmitted power crosses the cable once.

Is RG-6 interchangeable with 50-ohm cable?

The RG-6 model is 75 Ω. An impedance step changes the reflection even if the cable attenuation is attractive. Measure the port or design the transitions explicitly.

What does an extrapolated coax estimate mean?

The equation continues past the highest published point for the named RG cable. Treat the value as a rough comparison and verify an assembly datasheet or measurement at that frequency.