−10 dB S11 to VSWR and Return Loss

Convert a VNA log-magnitude S₁₁ of −10 dB to positive return loss, 10% reflected power and about 1.92:1 VSWR.

Jump to results ↓

Inputs

Measured value
For VSWR enter the number before :1. Use ∞ for an infinite loss or VSWR.

Results

Preset estimate
Voltage standing wave ratio 1.925:1
Reflection coefficient |Γ|
0.31623
Return loss
10 dB
Mismatch loss
0.458 dB
Accepted and reflected RF power splitINCIDENT POWERAccepted 90%Reflected 10%
Percentages refer to incident power at the load reference plane.

Single-port power

Accepted power
90 %
Reflected power
10 %

Worked example

On a VNA log-magnitude display, S₁₁ = −10 dB corresponds to +10 dB of return loss. Select positive return loss and enter 10. The reflected power is 10% of the incident power.

Check the calibration reference and trace format when comparing instruments. A Smith chart, a magnitude plot and an SWR trace can all describe the same reflection in different ways.

Voltage standing wave ratio
1.925 :1
Reflection coefficient |Γ|
0.31623
Return loss
10 dB
Mismatch loss
0.458 dB

Formulas & assumptions

  • |Γ| = (VSWR − 1)/(VSWR + 1). VSWR = (1 + |Γ|)/(1 − |Γ|).
  • Return loss = −20 log₁₀|Γ|. Mismatch loss = −10 log₁₀(1 − |Γ|²).
  • Reflected power = 100 × |Γ|² percent. Accepted power = 100 × (1 − |Γ|²) percent.

Use the measurement at the antenna or load reference plane. A lossy feed can make return loss look better at the radio end. A VNA’s log-magnitude S₁₁ usually uses the opposite sign from positive return loss.

Accepted power can become radiation or heat. This single-port converter does not determine antenna efficiency or the phase of the reflection.

Questions & answers

Do I enter −10 or +10 when the VNA shows −10 dB S11?

Enter +10 in the positive return-loss mode. The VNA log-magnitude sign is reversed.

What is the reflection coefficient amplitude for −10 dB S11?

It is 10^(−10/20), or about 0.316. The reflected power fraction is its square, 0.1.