868 MHz Woodland LoRa Fade Margin

Test how a 25 dB woodland loss allowance affects a 5 km 868 MHz LoRa link with a 10 dB fade target.

Jump to results ↓

Inputs

Path & receiver threshold
Transmit chain
Receive chain

Results

Preset estimate
Available fade margin 8.8dB

Below fade target

Received level
-115.2 dBm
Free-space path loss
105.2 dB
Reserve after target
-1.2 dB
RF link level waterfallSIGNAL LEVEL / dBm13TX12TX feed14.2EIRP-116Path-113.9RX ant.-115.2RX port
Cumulative levels in dBm. Dashed copper marks the receiver sensitivity of -124 dBm.

Chain breakdown

At TX antenna port
12 dBm
EIRP
14.15 dBm
ERP
12 dBm
At RX antenna port
-113.9 dBm
Receiver threshold
-124 dBm
Max free-space loss at target
104 dB
Free-space range at target
4.36 km

Worked example

The 25 dB woodland allowance is a test assumption. Vary it after measuring received power on the intended route, with the antenna height and leaf conditions you expect to use.

Compare margin before and after the additional loss. If foliage consumes the reserve, antenna relocation or a shorter relay hop may help. Use the clearance calculator to see whether raising an endpoint moves the ray above the canopy.

Available fade margin
8.8 dB
Received level
-115.2 dBm
Free-space path loss
105.2 dB
Reserve after target
-1.2 dB

Formulas & assumptions

  • FSPL = 20 log₁₀(4πd/λ), with d and λ in the same units. Doubling distance adds about 6.02 dB.
  • EIRP = TX power − TX cable and connector loss + TX antenna gain.
  • RX power = EIRP − FSPL − extra path loss + RX antenna gain − RX cable and connector loss.
  • Available fade margin = RX power − sensitivity. Reserve after target = available margin − desired margin.

Use antenna gains for the intended direction and cable loss at the chosen frequency. Use sensitivity for the modulation, channel width and packet error criterion.

Friis assumes far-field free space. Terrain, vegetation, polarization, multipath and interference can dominate a real link. Add known impairments under other losses and check the Fresnel path.

References

Questions & answers

Where is woodland attenuation entered in a LoRa link budget?

Enter a measured or assumed increment in Other path losses. Keep radio feed loss and the desired fade reserve in their respective fields.

Is 25 dB a standard loss for every 868 MHz woodland path?

The 25 dB value is a scenario to test. Depth, moisture, leaf cover and antenna height affect the real path loss.