100 Ω Gigabit Ethernet MDI pair

An MDI pair fans out from a PHY to magnetics on the top layer.

Readout

Hammerstad–Jensen / Cohn
Z DIFF
107.95Ω
Z ODD
53.975Ω
Z EVEN
66.202Ω
Z COMMON
33.101Ω
Within targetWithin the ±10% screening band.
Differential pair live schematicEdge-coupled surface pairODD / EVENS 0.21 mmEven · same phaseOdd · opposite phaseDk 4.25Gap sensitivity · Zdiff (Ω)S / W73.91001270.180.9495DifferentialEdge gap / widthLOW ZdiffTARGET 100 ΩHIGH Zdiff

Mode & timing results

QuantityValue
Single-ended reference60.287 Ω
Target margin+7.9495%
Coupling kᵦ0.10174
Odd / even effective Dk2.8993 / 3.3577
Skew phase at bit rate1.8 °
Unit interval800 ps
Rise-time knee1.9444 GHz

How to read this result

Differential drive gives 2 × Zodd. Common-mode drive puts the two lines in parallel and gives Zeven / 2. Skew phase is reported at the entered bit rate. Rise time estimates the edge bandwidth as 0.35 / tr.

Hammerstad–Jensen and Cohn give quasi-static modal impedances for symmetric pairs. Finite copper uses an equivalent-width correction. Etch shape, fiber weave, asymmetry and dielectric dispersion require stackup validation.

Methods & references

Differential pair examples

All 50 examples