56 Gb/s SerDes skew check

An inner-layer link has a small measured delay difference between pair members.

Readout

Hammerstad–Jensen / Cohn
Z DIFF
111.77Ω
Z ODD
55.887Ω
Z EVEN
66.417Ω
Z COMMON
33.209Ω
Target offsetThe pair is outside the ±10% screening band.
Differential pair live schematicSymmetric striplineODD / EVENS 0.17 mmEven · same phaseOdd · opposite phaseDk 3.35Gap sensitivity · Zdiff (Ω)S / W69.299.51300.180.9495DifferentialEdge gap / widthLOW ZdiffTARGET 100 ΩHIGH Zdiff

Mode & timing results

QuantityValue
Single-ended reference61.323 Ω
Target margin+11.773%
Coupling kᵦ0.086104
Odd / even effective Dk3.35 / 3.35
Skew phase at bit rate-34.272 °
Unit interval17.857 ps
Rise-time knee29.167 GHz

How to read this result

Differential drive gives 2 × Zodd. Common-mode drive puts the two lines in parallel and gives Zeven / 2. Skew phase is reported at the entered bit rate. Rise time estimates the edge bandwidth as 0.35 / tr.

Hammerstad–Jensen and Cohn give quasi-static modal impedances for symmetric pairs. Finite copper uses an equivalent-width correction. Etch shape, fiber weave, asymmetry and dielectric dispersion require stackup validation.