An outer-layer USB route uses a 0.15 mm signal-to-plane stackup.
85 Ω PCIe Gen4 inner-layer pair
A symmetric stripline pair carries lane traffic between the CPU and a card connector.
Readout
Hammerstad–Jensen / CohnMode & timing results
| Quantity | Value |
|---|---|
| Single-ended reference | 57.943 Ω |
| Target margin | +24.698% |
| Coupling kᵦ | 0.082997 |
| Odd / even effective Dk | 3.75 / 3.75 |
| Skew phase at bit rate | 11.52 ° |
| Unit interval | 62.5 ps |
| Rise-time knee | 15.909 GHz |
How to read this result
Differential drive gives 2 × Zodd. Common-mode drive puts the two lines in parallel and gives Zeven / 2. Skew phase is reported at the entered bit rate. Rise time estimates the edge bandwidth as 0.35 / tr.
Hammerstad–Jensen and Cohn give quasi-static modal impedances for symmetric pairs. Finite copper uses an equivalent-width correction. Etch shape, fiber weave, asymmetry and dielectric dispersion require stackup validation.