85 Ω PCIe Gen4 inner-layer pair

A symmetric stripline pair carries lane traffic between the CPU and a card connector.

Readout

Hammerstad–Jensen / Cohn
Z DIFF
105.99Ω
Z ODD
52.997Ω
Z EVEN
62.59Ω
Z COMMON
31.295Ω
Target offsetThe pair is outside the ±10% screening band.
Differential pair live schematicSymmetric striplineODD / EVENS 0.2 mmEven · same phaseOdd · opposite phaseDk 3.75Gap sensitivity · Zdiff (Ω)S / W6593.81230.180.9495DifferentialEdge gap / widthLOW ZdiffTARGET 85 ΩHIGH Zdiff

Mode & timing results

QuantityValue
Single-ended reference57.943 Ω
Target margin+24.698%
Coupling kᵦ0.082997
Odd / even effective Dk3.75 / 3.75
Skew phase at bit rate11.52 °
Unit interval62.5 ps
Rise-time knee15.909 GHz

How to read this result

Differential drive gives 2 × Zodd. Common-mode drive puts the two lines in parallel and gives Zeven / 2. Skew phase is reported at the entered bit rate. Rise time estimates the edge bandwidth as 0.35 / tr.

Hammerstad–Jensen and Cohn give quasi-static modal impedances for symmetric pairs. Finite copper uses an equivalent-width correction. Etch shape, fiber weave, asymmetry and dielectric dispersion require stackup validation.

Methods & references

Differential pair examples

All 50 examples