RobotKinematicsLab

ABB index-table approach

A two-axis layout is used for an early clearance study at a rotary indexing station.

Results ↓

Parameters

Geometry
m
m
Forward pose
°
°
Inverse target
m
m
Joint limits
°
°
°
°

Live results

Warn

Only one inverse branch is inside the joint limits.

Tool X
0.407839 m
Tool Y
0.470178 m
Tool angle
90 °
IK branches
1 / 2
Workspace and elbow branches
Workspace and elbow branchesXY WORK PLANECLOSED REACH RINGWorkspace ringREACH WINDOW
  • Entered pose
  • Elbow-up
  • Elbow-down
Reach and limits
QuantityValue
Wrist radius0.463249 m
Inner radius0.17 m
Outer radius0.73 m
Signed ring clearance0.266751 m
Wrist X0.39 m
Wrist Y0.25 m
Joint solutions
Poseθ1θ2Limit check
Forward input25 °65 °J1 OK · J2 OK
Elbow-up68.332 °-105.254 °J1 OK · J2 OUT
Elbow-down-3.01022 °105.254 °J1 OK · J2 OK

Formula trace

  1. Forward pose

    x = Σ Lᵢ cos(Σ θⱼ), y = Σ Lᵢ sin(Σ θⱼ), φ = Σ θᵢ

    x = 0.407839 my = 0.470178 mφ = 90 °

    Lengths yield a Cartesian position. Trigonometry uses radians internally.

  2. Closed reach ring

    w = target − L₃[cos φ, sin φ] (3R); |L₁ − L₂| ≤ ‖w‖ ≤ L₁ + L₂

    rmin = 0.17 mr = 0.463249 mrmax = 0.73 m

    Compare wrist radius and ring edges in one length unit before solving angles.

  3. Inverse branches

    θ₂ = ±2 atan2(√(rₘₐₓ²−r²), √(r²−rₘᵢₙ²)); θ₁ = atan2(wᵧ,wₓ) − atan2(L₂ sin θ₂,L₁+L₂ cos θ₂)

    θ₂ up = -105.254 °θ₂ down = 105.254 °

    Elbow-up uses a negative principal θ₂ with +Y up. θ₃ = φ − θ₁ − θ₂ when active.