RobotKinematicsLab

Cleanroom wafer handoff

A planar wafer transfer arm needs a fixed blade direction at the cassette opening.

Results ↓

Parameters

Geometry
m
m
m
Forward pose
°
°
°
Inverse target
m
m
°
Joint limits
°
°
°
°
°
°

Live results

Pass

Both inverse branches are reachable and within the joint limits.

Tool X
0.660157 m
Tool Y
0.394491 m
Tool angle
10 °
IK branches
2 / 2
Workspace and elbow branches
Workspace and elbow branchesXY WORK PLANECLOSED REACH RINGWorkspace ringREACH WINDOW
  • Entered pose
  • Elbow-up
  • Elbow-down
Reach and limits
QuantityValue
Wrist radius0.469419 m
Inner radius0.08 m
Outer radius0.64 m
Signed ring clearance0.170581 m
Wrist X0.453342 m
Wrist Y0.121797 m
Joint solutions
Poseθ1θ2θ3Limit check
Forward input15 °55 °-60 °J1 OK · J2 OK · J3 OK
Elbow-up51.5767 °-86.4868 °44.9101 °J1 OK · J2 OK · J3 OK
Elbow-down-21.5001 °86.4868 °-54.9866 °J1 OK · J2 OK · J3 OK

Formula trace

  1. Forward pose

    x = Σ Lᵢ cos(Σ θⱼ), y = Σ Lᵢ sin(Σ θⱼ), φ = Σ θᵢ

    x = 0.660157 my = 0.394491 mφ = 10 °

    Lengths yield a Cartesian position. Trigonometry uses radians internally.

  2. Closed reach ring

    w = target − L₃[cos φ, sin φ] (3R); |L₁ − L₂| ≤ ‖w‖ ≤ L₁ + L₂

    rmin = 0.08 mr = 0.469419 mrmax = 0.64 m

    Compare wrist radius and ring edges in one length unit before solving angles.

  3. Inverse branches

    θ₂ = ±2 atan2(√(rₘₐₓ²−r²), √(r²−rₘᵢₙ²)); θ₁ = atan2(wᵧ,wₓ) − atan2(L₂ sin θ₂,L₁+L₂ cos θ₂)

    θ₂ up = -86.4868 °θ₂ down = 86.4868 °

    Elbow-up uses a negative principal θ₂ with +Y up. θ₃ = φ − θ₁ − θ₂ when active.