RoomAcousticLab · Calculation record
Shift noise dose example
Shift below 80 dBA
All task levels fall below the OSHA hearing-conservation and NIOSH meter thresholds. Compare those channels with continuous 3 dB integration.
Inputs
Set any unused segment duration to zero.
- OSHA HC dose
- 0%
- OSHA HC TWA
- —
- NIOSH dose
- 0%
- NIOSH TWA
- —
Shift exposure timeline
Illustrative scaleBelow the listed exposure levels
PassThe entered unprotected segments fall below the screened action level and dose criteria.
Below actionAction levelAt / over limit
Input snapshot
- Segment 1 level
- 79 dBA
- Segment 1 duration
- 5 h
- Segment 2 level
- 76 dBA
- Segment 2 duration
- 3 h
- Segment 3 level
- 82 dBA
- Segment 3 duration
- 0 h
- Segment 4 level
- 75 dBA
- Segment 4 duration
- 0 h
- Protection
- None
Calculation breakdown
- Total measured duration
- 8 h
- OSHA PEL dose · 90 dBA threshold
- 0%
- OSHA PEL TWA
- No qualifying segment
- Continuous 3 dB dose · no threshold
- 20.3%
- Continuous 3 dB TWA
- 78.1 dBA
- Estimated protector attenuation
- 0 dB
- Estimated protected OSHA HC TWA
- No qualifying segment
| Segment | Exposure | Length |
|---|---|---|
| 1 | 79 dBA | 5 h |
| 2 | 76 dBA | 3 h |
| 3 | Inactive | 0 h |
| 4 | Inactive | 0 h |
The A-weighted NRR estimate applies a 50% field factor to the adjusted label. Use the higher labelled NRR for dual protection. The exposure screen uses unprotected data. Personal dosimetry, fit testing and separate assessment of impulsive or peak noise are needed for workplace decisions.