Noise barrier example

Grazing sight line

The source, receiver and barrier tip have equal elevations. The path difference is zero, which gives the model’s grazing estimate.

Inputs

Barrier section
Frequency & target
Insertion loss
4.8dB
Fresnel N
0
Path diff.
0m
Tip clearance
0m

Barrier cross-section & ray paths

Illustrative scale
Noise barrier ray geometryThe indigo sight line joins source and receiver and the teal ray follows the top of the wall or berm. The two horizontal distances and all three heights update with the inputs.SOURCEWALL TIPRECEIVER1.5 m1.5 m1.5 md₁ 7 md₂ 13 m
DiffractedSight lineBarrier

Sight line reaches the receiver

Review

A grazing or illuminated path has limited screening. The negative-Fresnel roll-off is an approximation.

≥ 2 dB reserveGrazing / reviewBelow target

Calculation breakdown

Source to tip A
7 m
Tip to receiver B
13 m
Direct path d
20 m
Wavelength λ
0.343 m
Diffraction zone
Grazing
Uncapped estimate
4.77 dB
Practical screening cap
20 dB
Target margin
0.77 dB