RoomAcousticLab · Calculation record
Noise barrier insertion loss
Trace the direct and diffracted paths over a barrier and estimate frequency-specific insertion loss.
Inputs
- Insertion loss
- 13.5dB
- Fresnel N
- 0.974
- Path diff.
- 0.334m
- Tip clearance
- 1.9m
Barrier cross-section & ray paths
Illustrative scaleInsertion-loss target cleared
PassThe estimate clears the entered target by at least 2 dB.
≥ 2 dB reserveGrazing / reviewBelow target
Input snapshot
- Source height
- 1.2 m
- Receiver height
- 1.5 m
- Barrier height
- 3.2 m
- Source to barrier
- 8 m
- Barrier to receiver
- 16 m
- Barrier type
- Thin wall · 20 dB cap
- Band frequency
- 500 Hz
- Air temperature
- 20 °C
- Target insertion loss
- 10 dB
Calculation breakdown
- Source to tip A
- 8.246 m
- Tip to receiver B
- 16.09 m
- Direct path d
- 24.002 m
- Wavelength λ
- 0.686 m
- Diffraction zone
- Shadow
- Uncapped estimate
- 13.52 dB
- Practical screening cap
- 20 dB
- Target margin
- 3.52 dB
The section assumes a continuous, acoustically opaque barrier with one dominant top edge. Finite length, ground effects, reflection and sound through the barrier can change the actual insertion loss.