RoomAcousticLab · Calculation record
Shift noise dose example
Twelve-hour manufacturing shift
Four equal-duration tasks make up a longer-than-eight-hour shift. Keep the TWA reference at eight hours and check the dose accumulated over all twelve.
Inputs
Set any unused segment duration to zero.
- OSHA HC dose
- 90.3%
- OSHA HC TWA
- 89.3dBA
- NIOSH dose
- 282.7%
- NIOSH TWA
- 89.5dBA
Shift exposure timeline
Illustrative scaleAn exposure criterion is reached
LimitOSHA PEL dose or NIOSH dose using the 80 dBA threshold is at or above 100%. This screen uses unprotected exposure.
Below actionAction levelAt / over limit
Input snapshot
- Segment 1 level
- 82 dBA
- Segment 1 duration
- 3 h
- Segment 2 level
- 88 dBA
- Segment 2 duration
- 3 h
- Segment 3 level
- 92 dBA
- Segment 3 duration
- 3 h
- Segment 4 level
- 77 dBA
- Segment 4 duration
- 3 h
- Protection
- Single protector
- Label NRR (higher if dual)
- 21 dB
Calculation breakdown
- Total measured duration
- 12 h
- OSHA PEL dose · 90 dBA threshold
- 49.5%
- OSHA PEL TWA
- 84.9 dBA
- Continuous 3 dB dose · no threshold
- 288.6%
- Continuous 3 dB TWA
- 89.6 dBA
- Estimated protector attenuation
- 7 dB
- Estimated protected OSHA HC TWA
- 82.3 dBA
| Segment | Exposure | Length |
|---|---|---|
| 1 | 82 dBA | 3 h |
| 2 | 88 dBA | 3 h |
| 3 | 92 dBA | 3 h |
| 4 | 77 dBA | 3 h |
The A-weighted NRR estimate applies a 50% field factor to the adjusted label. Use the higher labelled NRR for dual protection. The exposure screen uses unprotected data. Personal dosimetry, fit testing and separate assessment of impulsive or peak noise are needed for workplace decisions.