Office door in a rated wall

A lower-performing door occupies a small fraction of a wall. Compare the resulting band transmission loss with the solid partition and the selected target.

Inputs

Primary partition
Weak element & opening
Composite TL
39dB
Wall penalty
12.98dB
Open gap
0%
Target margin
-2.98dB

Partition elevation & leak response

Illustrative scale
Partition elevation and transmission loss curveA wall elevation shows the weak element and a visually enlarged gap. The curve plots composite transmission loss against the logarithmic gap share.PARTITION ELEVATIONTL VS OPEN GAP20 m² totalDoor0%5%Current 39 dB
WallWeak elementOpen leak

Transmission target shortfall

Limit

The modelled value falls on the wrong side of the entered target.

≥ 3 dB reserve0–3 dB reserveBelow target

Calculation breakdown

Solid wall area
18.1 m²
Weak element share
9.5%
Transmission loss with the gap sealed
39.02 dB
Target band TL
42 dB
Leak area sensitivity
Open areaComposite TLWall penalty
0%39.02 dB12.98 dB
0.001%38.69 dB13.313 dB
0.01%36.47 dB15.528 dB
0.1%29.49 dB22.513 dB
1%19.95 dB32.054 dB
5%13 dB39.001 dB