Partition transmission example

Sealed archive wall

A homogeneous wall has no separate door or gap in the tested area. Its composite result should match the entered wall TL exactly.

Inputs

Primary partition
Weak element & opening
Composite TL
49dB
Wall penalty
0dB
Open gap
0%
Target margin
6dB

Partition elevation & leak response

Illustrative scale
Partition elevation and transmission loss curveA wall elevation shows the weak element and a visually enlarged gap. The curve plots composite transmission loss against the logarithmic gap share.PARTITION ELEVATIONTL VS OPEN GAP18 m² totalSolid assembly0%5%Current 49 dB
WallWeak elementOpen leak

Transmission target cleared

Pass

The estimate clears the entered target by at least 3 dB.

≥ 3 dB reserve0–3 dB reserveBelow target

Calculation breakdown

Solid wall area
18 m²
Weak element share
0%
Transmission loss with the gap sealed
49 dB
Target band TL
43 dB
Leak area sensitivity
Open areaComposite TLWall penalty
0%49 dB0 dB
0.001%46.46 dB2.539 dB
0.01%39.49 dB9.515 dB
0.1%29.95 dB19.054 dB
1%19.99 dB29.005 dB
5%13.01 dB35.991 dB