Shift noise dose example

Full shift at the OSHA action level

Eight hours at 85 dBA reaches the hearing-conservation action level and the NIOSH REL. The OSHA PEL dosimeter channel excludes this segment.

Inputs

Exposure segments
Protector estimate

Set any unused segment duration to zero.

OSHA HC dose
50%
OSHA HC TWA
85dBA
NIOSH dose
100%
NIOSH TWA
85dBA

Shift exposure timeline

Illustrative scale
Shift-noise level by exposure durationFour step segments show time and measured A-weighted level. Dashed lines mark the OSHA action level and PEL criterion.A-WEIGHTED LEVELSEGMENT TIMES10 h8 h85 dBA action90 dBA PEL
Lower exposureAction levelPEL band

An exposure criterion is reached

Limit

OSHA PEL dose or NIOSH dose using the 80 dBA threshold is at or above 100%. This screen uses unprotected exposure.

Below actionAction levelAt / over limit

Calculation breakdown

Total measured duration
8 h
OSHA PEL dose · 90 dBA threshold
0%
OSHA PEL TWA
No qualifying segment
Continuous 3 dB dose · no threshold
100%
Continuous 3 dB TWA
85 dBA
Estimated protector attenuation
9 dB
Estimated protected OSHA HC TWA
76 dBA
Entered shift segments
SegmentExposureLength
185 dBA8 h
2Inactive0 h
3Inactive0 h
4Inactive0 h