Shift noise dose example

Short, high-noise maintenance task

A 15-minute maintenance task dominates the shift dose. Check the effect of its high energy and the warning for a segment above 115 dBA.

Inputs

Exposure segments
Protector estimate

Set any unused segment duration to zero.

OSHA HC dose
132%
OSHA HC TWA
92dBA
NIOSH dose
5,079.7%
NIOSH TWA
102dBA

Shift exposure timeline

Illustrative scale
Shift-noise level by exposure durationFour step segments show time and measured A-weighted level. Dashed lines mark the OSHA action level and PEL criterion.A-WEIGHTED LEVELSEGMENT TIMES20 h8 h85 dBA action90 dBA PEL
Lower exposureAction levelPEL band

Segment exceeds 115 dBA

Limit

A continuous segment above 115 dBA is outside OSHA Table G-16. Assess short-duration and peak exposure separately.

Below actionAction levelAt / over limit

Calculation breakdown

Total measured duration
8 h
OSHA PEL dose · 90 dBA threshold
132%
OSHA PEL TWA
92 dBA
Continuous 3 dB dose · no threshold
5,087.3%
Continuous 3 dB TWA
102 dBA
Estimated protector attenuation
12.5 dB
Estimated protected OSHA HC TWA
79.5 dBA
Entered shift segments
SegmentExposureLength
1117 dBA0.25 h
274 dBA7.75 h
3Inactive0 h
4Inactive0 h