Methodology
Equations, frequency-band assumptions and interpretation for each RoomAcousticLab calculator. Use the results to screen design options and plan measurements.
Reverberation time & panel area
A = Σ(Sᵢ αᵢ), ᾱ = A / SRT₆₀,Sabine = kV / A, RT₆₀,Eyring = kV / [−S ln(1 − ᾱ)]RT₆₀,Fitzroy = (kV / S²) Σ[Sᵢ / −ln(1 − αᵢ)]αᵢ,after = αᵢ + (Sₚ / Sᵢ)(αₚ − αᵢ)Use room dimensions and absorption coefficients for a single frequency band. Each Sᵢ is the area of one opposite pair of surfaces. The entered coefficient is the baseline for both faces of that pair. The temperature-corrected constant is 0.161 × c(20 °C)/c(T) in SI. The same constant is about 0.049 in US units, with an exact internal conversion for parity.
Panel area replaces material on the selected pair. Enter the actual usable area if treatment can cover only one face or part of a face. Sabine and Eyring are inverted analytically. Fitzroy is solved by a bounded search over the selected pair. Zero absorption gives no finite decay for the relevant model, and unity absorption is a limiting case.
Use Sabine in the low-absorption regime, Eyring for a more evenly distributed field, and Fitzroy when opposite pairs differ. The models omit air absorption, leakage and non-diffuse geometry. Measured decay and installed band coefficients should drive a final specification.
Open calculatorRoom modes & Schroeder frequency
c(T) = 331.3 √(1 + T°C / 273.15)fₙ = (c / 2) √[(nₓ / L)² + (nᵧ / W)² + (n_z / H)²]fₛ = 2000 √(RT₆₀ / Vₘ³)One, two and three nonzero indices identify axial, tangential and oblique modes. The solver expands its index range until all of the lowest 24 frequencies and the requested band counts are covered. The first 18 modes are plotted. The largest gap compares up to the first 12 distinct positions within the ranked list. A separation of 0.1 Hz or less counts as a coincidence and a gap above 20 Hz flags sparse spacing.
Bolt uses an approximate graphical boundary in plan length/width and height/width coordinates. Its classification is approximate near the drawn boundary. The Bonello screen uses full nominal 20–200 Hz one-third-octave bands below Schroeder. Counts should stay level or increase with frequency. A band with a coincidence needs at least five modes to clear this screen.
Rigid rectangular boundaries give ideal eigenfrequencies. Construction details, source and listener placement, surface impedance and damping affect measured levels. The Schroeder frequency is an approximate crossover.
Open calculatorComposite partition transmission loss
τ = 10^(−TL / 10), τ_comp = Σ(Sᵢ τᵢ) / S_totalTL_comp = −10 log₁₀(τ_comp), penalty = TL_wall − TL_compτ_gap = 1Use transmission loss values for the same band and testing basis. The element and open gap replace part of the solid wall. The gap transmits all incident energy in this approximation. The sweep keeps element area fixed and varies the ideal open share.
Matched single-number ratings can provide a rough comparison. A rated composite STC requires a frequency-band TL curve and the ASTM E413 fitting procedure. Treat indirect structure-borne and duct transmission as separate paths.
Open calculatorIndoor sound field & critical distance
R = S ᾱ / (1 − ᾱ), D_c = √[Q R / (16π)]Lₚ = L_w + 10 log₁₀[Q / (4πr²) + 4 / R]ΔL_diffuse = 10 log₁₀(R_after / R_before)Enter one source power and an average absorption coefficient for the same band. A point-source direct term and a spatially uniform reverberant term are summed by energy. At critical distance the two terms are equal. Close to a real source its physical extent can invalidate the point-source approximation.
Doubling mean absorption is bounded by unity. Ceiling replacement changes equivalent absorption by area times the coefficient difference. The diffuse-only improvement and total receiver improvement use separate energy ratios, so the direct field can limit the benefit.
At ᾱ = 1, R diverges and the diffuse term vanishes. At ᾱ = 0, the ideal enclosure has no finite steady-state reverberant level. The model omits discrete room modes and early-reflection interference.
Open calculatorOutdoor noise propagation & setback
Point: Lₚ = L_w + 10 log₁₀(Q) − 10 log₁₀(4π) − 20 log₁₀(r) − A_air + ΔL_NInfinite line: Lₚ = L_w/m + 10 log₁₀[Q / (4r)] − A_air + ΔL_NFinite line: add 10 log₁₀[(2/π) atan(L / (2r))] to the infinite-line estimateA_air = α_air r / 1000, ΔL_N = 10 log₁₀(N) for incoherent sourcesThe divergence formulas use metres. Q = 1, 2, 4 and 8 represent full, half, quarter and eighth space in the point model. The line model integrates the squared pressure of uniformly distributed, mutually incoherent point radiators and applies Q as a directivity multiplier. The finite line is viewed at its perpendicular midpoint. Far away it approaches the level of a point source with the same total acoustic power.
Use a supplied atmospheric coefficient for the represented band and conditions. It is applied to perpendicular range in the line cases. Source power per metre converts to per foot by adding 10 log₁₀(0.3048). Identical sources share the same range and directivity. The optional perfectly in-phase sum adds 20 log₁₀(N) as an ideal case.
Setback is solved between 0.1 m and 100 km. This model considers divergence and the entered air loss. A site study can include ground impedance, shielding, weather, reflections, background and source spectra as required by the governing method.
Open calculatorNoise barrier insertion loss
A = hypot(d₁, h_b − h_s), B = hypot(d₂, h_b − h_r)d = hypot(d₁ + d₂, h_r − h_s), δ = sign(clearance) × (A + B − d)N = 2δ / λ, λ = c / f, IL = 10 log₁₀(3 + 20N)Tip clearance is measured upward from the straight source-to-receiver sight line at the barrier. A positive clearance is in shadow. The path-length subtraction is rationalized so nearly grazing paths retain their small signed difference.
Use the logarithmic estimate at N ≥ −0.05. In the illuminated region the calculator linearly joins its value at N = −0.05 to zero at N = −0.20, and then holds zero. The thin-wall and berm settings cap the single-edge estimate at 20 and 24 dB respectively as practical screening assumptions.
The section assumes a continuous, acoustically opaque barrier with one dominant top edge. Finite length, ground effects, reflection and sound through the barrier can change the actual insertion loss.
Open calculatorOSHA & NIOSH shift noise dose
Allowed duration at L: T = 8 × 2^[(criterion − L) / exchange]Dose = 100 Σ(tᵢ / Tᵢ), TWA = criterion + exchange × log₂(Dose / 100)Single attenuation = max[0, (NRR − 7) / 2], dual = single + 5 dBEnter representative A-weighted task levels and durations. Zero hours excludes a segment. The OSHA hearing-conservation (HC) and PEL channels both use 90 dBA and a 5 dB exchange. HC integrates levels at or above 80 dBA and reaches action at 50% dose or 85 dBA TWA. PEL integrates at or above 90 dBA and is screened at 100% dose.
NIOSH uses an 85 dBA criterion, a 3 dB exchange rate and an 80 dBA threshold. The breakdown also shows a separate continuous 3 dB comparison that includes all entered active levels. Each TWA uses eight reference hours, including for longer measured shifts. Zero qualifying dose has no logarithmic TWA.
The A-weighted NRR estimate applies a 50% field factor to the adjusted label. Use the higher labelled NRR for dual protection. The exposure screen uses unprotected data. Personal dosimetry, fit testing and separate assessment of impulsive or peak noise are needed for workplace decisions.
Open calculatorHelmholtz resonator tuning
f₀ = [c / (2π)] √[P / (D(t + δ_end))], f_quarter = c / (4D)Holes: δ_end = 0.85d F(√P), linear F(x) = 1 − 1.4xFok F(x) = 1 − 1.4092x + 0.33818x³ + 0.06793x⁵ − 0.02287x⁶ + 0.003015x⁷ − 0.01614x⁸Slots: P = w / (w + slat width), δ_end = −(2w/π) ln[sin(πP/2)]The model balances the mass of air in a short opening against the stiffness of sealed cavity air. The two-sided correction is based on round-hole radiation with linear or polynomial hole interaction. Hole pitch assumes a square grid. The slat option uses an ideal long-slit correction and pitch equal to slot plus slat width.
The compactness screen compares depth, effective neck and opening pitch with one eighth of the predicted wavelength. Open area above 25% is flagged for model review. Tuning error is signed in hertz and screened at 5% and 15% of the target in absolute terms.
The tuning estimate assumes a rigid panel, rigid backing and small-signal motion. Surface resistance, porous backing, construction tolerances and leakage affect measured absorption and bandwidth.
Open calculator