RoomAcousticLab · Calculation record
Indoor sound field & critical distance
Split direct and reverberant sound at a receiver and estimate the benefit of acoustic ceiling treatment.
Inputs
- Sound level
- 86dB
- Critical dist.
- 1.17m
- Direct share
- 7.9%
- Level drop
- 3.45dB
Direct and reflected energy paths
Illustrative scaleReceiver target exceeded
LimitThe modelled value falls on the wrong side of the entered target.
≥ 3 dB reserveReviewOver target
Input snapshot
- Total surface area
- 180 m²
- Mean absorption α
- 0.16
- Sound power Lw
- 95 dB
- Directivity Q
- 2 · Half space
- Receiver distance
- 4 m
- Receiver target
- 83 dB
- Treatment option
- Double mean absorption
Calculation breakdown
- Room constant R
- 34.29 m²
- Direct level
- 74.98 dB
- Reverberant level
- 85.67 dB
- Receiver regime
- Reverberant dominated
- Treated mean absorption α
- 0.32
- Treated receiver level
- 82.57 dB
- Diffuse-only level drop
- 3.93 dB
At ᾱ = 1, R diverges and the diffuse term vanishes. At ᾱ = 0, the ideal enclosure has no finite steady-state reverberant level. The model omits discrete room modes and early-reflection interference.