Bearing Fault Frequency Calculator
Locate raceway, rolling element and cage lines in Hz, CPM and shaft orders, including the second harmonics.
Live results
Bearing geometry & order spectrum- BPFO
- 109.94Hz
- BPFI
- 157.06Hz
- BSF
- 78.665Hz
- FTF
- 12.216Hz
Bearing geometry
Within screenThe diameter inequality is satisfied. Use the markers as search frequencies in a measured spectrum.
Operating inputs
Calculation details
| Shaft rotational frequency | 29.6667 Hz |
|---|---|
| Shaft rotational frequency | 1,780 CPM |
| Strict element-diameter ceiling | 50.2281 mm |
| Diameter below ceiling | 40.7281 mm |
Order and harmonic markers
| Line | Hz | CPM | Order | 2× Hz | 2× CPM | 2× order |
|---|---|---|---|---|---|---|
| BPFO | 109.94 | 6,596.5 | 3.7059 | 219.88 | 13,193 | 7.4118 |
| BPFI | 157.06 | 9,423.5 | 5.2941 | 314.12 | 18,847 | 10.588 |
| BSF | 78.665 | 4,719.9 | 2.6516 | 157.33 | 9,439.7 | 5.3032 |
| FTF | 12.216 | 732.94 | 0.41177 | 24.431 | 1,465.9 | 0.82353 |
Model & assumptions
Use the geometry for one row, the inner-ring speed and a stationary outer ring. Search around the calculated orders and check harmonics and sidebands against a measured envelope spectrum. A rolling-element defect often appears at 2× BSF.
Bd must be strictly below Pd·cos φ. The kinematic model assumes rolling contact without slip. The spectrum shows calculated locations, and the marker height carries no amplitude information.
Methodology and references ↗RotorVibLab · SI · Engineering calculation
Bearing Fault Frequency Calculator
q = (Bd/Pd)·cos φ · FTF = fr·(1−q)/2 · BPFO/BPFI = Nb·fr·(1∓q)/2 · BSF = fr·Pd·(1−q²)/(2·Bd)
Operating inputs
| Pitch diameter Pd | 52 mm |
|---|---|
| Element diameter Bd | 9.5 mm |
| Contact angle φ | 15 ° |
| Elements per row Nb | 9 |
| Running speed | 1,780 RPM |
Results
| BPFO | 109.942 Hz |
|---|---|
| BPFI | 157.058 Hz |
| BSF | 78.6646 Hz |
| FTF | 12.2157 Hz |
| Shaft rotational frequency | 29.6667 Hz |
| Shaft rotational frequency | 1,780 CPM |
| Strict element-diameter ceiling | 50.2281 mm |
| Diameter below ceiling | 40.7281 mm |
Order and harmonic markers
| Line | Hz | CPM | Order | 2× Hz | 2× CPM | 2× order |
|---|---|---|---|---|---|---|
| BPFO | 109.94 | 6,596.5 | 3.7059 | 219.88 | 13,193 | 7.4118 |
| BPFI | 157.06 | 9,423.5 | 5.2941 | 314.12 | 18,847 | 10.588 |
| BSF | 78.665 | 4,719.9 | 2.6516 | 157.33 | 9,439.7 | 5.3032 |
| FTF | 12.216 | 732.94 | 0.41177 | 24.431 | 1,465.9 | 0.82353 |
Bearing geometry. The diameter inequality is satisfied. Use the markers as search frequencies in a measured spectrum.