RotorVibLab
Menu

Convert accelerometer peak g at 3,600 CPM

A 1.2 g peak reading is associated with a single component at 3,600 CPM. A separate overall housing reading is available.

Units
Edit inputs ↓

Live results

Sinusoid & machine severity bands
Velocity RMS
22.073mm/s RMS
Accel. peak
1.2g pk
Velocity zone
Zone C
One sinusoidal cycle60 HzRMS velocity bandsmm/s RMSABCD2.34.57.1Measured overall5 mm/s RMS

ISO 20816-3 velocity bands

Review
Zone AZone BZone CZone D

Zone C uses the entered overall RMS reading.

Editable case inputs

Harmonic signal
g pk
CPM
Severity assessment
mm/s RMS

Calculation details

Tone frequency60 Hz
Tone frequency3,600 CPM
Peak velocity31.2155 mm/s pk
RMS acceleration0.848528 g RMS
RMS velocity used for zone5 mm/s RMS
A/B boundary2.3 mm/s RMS
B/C boundary4.5 mm/s RMS
C/D boundary7.1 mm/s RMS
Headroom to B/C-0.5 mm/s RMS

What to check

The input frequency is stored as 60 Hz. Compare the high-frequency acceleration with the corresponding velocity and displacement.

Model & assumptions

xpk = xpp/2 · vpk = 2πf·xpk · apk = (2πf)²·xpk · RMS = peak/√2

Enter one sinusoidal component to convert amplitude conventions. For zone screening, choose the RMS source and enter the maximum applicable measured broadband housing velocity at steady operation. Group 2 covers power above 15 kW up to 300 kW; group 1 covers larger machines. For electric machines, verify shaft-height criteria and support stiffness in the measurement direction.

This two-group calculator uses the ISO 20816-3:2022 velocity bands for groups 1 and 2. A value exactly at a boundary is shown in the higher zone. Apply the governing edition, machinery scope and measurement bandwidth on the job.

Methodology and references ↗