RotorVibLab
Menu

Rigid machine housing vibration in Zone D

A 130 kW traction test motor on a stiff base has 5.3 mm/s overall RMS. The 1× component contributes 3.6 mm/s.

Units
Edit inputs ↓

Live results

Sinusoid & machine severity bands
Velocity RMS
3.6mm/s RMS
Accel. peak
0.097206g pk
Velocity zone
Zone D
One sinusoidal cycle29.8 HzRMS velocity bandsmm/s RMSABCD1.42.84.5Measured overall5.3 mm/s RMS

ISO 20816-3 velocity bands

Outside screen
Zone AZone BZone CZone D

Zone D uses the entered overall RMS reading.

Editable case inputs

Harmonic signal
mm/s RMS
Hz
Severity assessment
mm/s RMS

Calculation details

Tone frequency29.8 Hz
Tone frequency1,788 CPM
Peak velocity5.09117 mm/s pk
RMS acceleration0.068735 g RMS
RMS velocity used for zone5.3 mm/s RMS
A/B boundary1.4 mm/s RMS
B/C boundary2.8 mm/s RMS
C/D boundary4.5 mm/s RMS
Headroom to B/C-2.5 mm/s RMS

What to check

The overall value exceeds the 4.5 mm/s C/D boundary. The lower individual tone remains useful for fault analysis.

Model & assumptions

xpk = xpp/2 · vpk = 2πf·xpk · apk = (2πf)²·xpk · RMS = peak/√2

Enter one sinusoidal component to convert amplitude conventions. For zone screening, choose the RMS source and enter the maximum applicable measured broadband housing velocity at steady operation. Group 2 covers power above 15 kW up to 300 kW; group 1 covers larger machines. For electric machines, verify shaft-height criteria and support stiffness in the measurement direction.

This two-group calculator uses the ISO 20816-3:2022 velocity bands for groups 1 and 2. A value exactly at a boundary is shown in the higher zone. Apply the governing edition, machinery scope and measurement bandwidth on the job.

Methodology and references ↗