RotorVibLab
Menu

Velocity peak on a flexible large machine

A flexibly supported large machine has a measured 34 Hz velocity component of 4.6 mm/s peak.

Units
Edit inputs ↓

Live results

Sinusoid & machine severity bands
Velocity RMS
3.2527mm/s RMS
Accel. peak
0.10021g pk
Velocity zone
Zone B
One sinusoidal cycle34 HzRMS velocity bandsmm/s RMSABCD3.57.111Measured overall6.2 mm/s RMS

ISO 20816-3 velocity bands

Within screen
Zone AZone BZone CZone D

Zone B uses the entered overall RMS reading.

Editable case inputs

Harmonic signal
mm/s pk
Hz
Severity assessment
mm/s RMS

Calculation details

Tone frequency34 Hz
Tone frequency2,040 CPM
Peak velocity4.6 mm/s pk
RMS acceleration0.0708567 g RMS
RMS velocity used for zone6.2 mm/s RMS
A/B boundary3.5 mm/s RMS
B/C boundary7.1 mm/s RMS
C/D boundary11 mm/s RMS
Headroom to B/C0.9 mm/s RMS

What to check

Convert the signal to RMS but use the 6.2 mm/s overall value for the machine band. Change support only if the measured direction justifies it.

Model & assumptions

xpk = xpp/2 · vpk = 2πf·xpk · apk = (2πf)²·xpk · RMS = peak/√2

Enter one sinusoidal component to convert amplitude conventions. For zone screening, choose the RMS source and enter the maximum applicable measured broadband housing velocity at steady operation. Group 2 covers power above 15 kW up to 300 kW; group 1 covers larger machines. For electric machines, verify shaft-height criteria and support stiffness in the measurement direction.

This two-group calculator uses the ISO 20816-3:2022 velocity bands for groups 1 and 2. A value exactly at a boundary is shown in the higher zone. Apply the governing edition, machinery scope and measurement bandwidth on the job.

Methodology and references ↗