RotorVibLab
Menu

Convert a 45 µm running-speed displacement

A 25 Hz sinusoidal signal measures 45 µm peak-to-peak at a rigid medium-power machine housing.

Units
Edit inputs ↓

Live results

Sinusoid & machine severity bands
Velocity RMS
2.4991mm/s RMS
Accel. peak
0.056611g pk
Velocity zone
Zone B
One sinusoidal cycle25 HzRMS velocity bandsmm/s RMSABCD1.42.84.5Tone only2.499 mm/s RMS

ISO 20816-3 velocity bands

Reference only
Zone AZone BZone CZone D

Zone B is a tone-only comparison. Use measured broadband RMS for the machine screen.

Editable case inputs

Harmonic signal
µm pk–pk
Hz
Severity assessment

Calculation details

Tone frequency25 Hz
Tone frequency1,500 CPM
Peak velocity3.53429 mm/s pk
RMS acceleration0.0400301 g RMS
RMS velocity used for zone2.49912 mm/s RMS
A/B boundary1.4 mm/s RMS
B/C boundary2.8 mm/s RMS
C/D boundary4.5 mm/s RMS
Headroom to B/C0.300878 mm/s RMS

What to check

Halve peak-to-peak before differentiating and divide peak velocity by √2. The tone can be compared with the bands as a screening value.

Model & assumptions

xpk = xpp/2 · vpk = 2πf·xpk · apk = (2πf)²·xpk · RMS = peak/√2

Enter one sinusoidal component to convert amplitude conventions. For zone screening, choose the RMS source and enter the maximum applicable measured broadband housing velocity at steady operation. Group 2 covers power above 15 kW up to 300 kW; group 1 covers larger machines. For electric machines, verify shaft-height criteria and support stiffness in the measurement direction.

This two-group calculator uses the ISO 20816-3:2022 velocity bands for groups 1 and 2. A value exactly at a boundary is shown in the higher zone. Apply the governing edition, machinery scope and measurement bandwidth on the job.

Methodology and references ↗