RotorVibLab
Menu

Rim-and-face pump alignment at cold condition

The pump feet are 160 and 475 mm from the first indicator plane. Both dials were zeroed at 12 o’clock before clocking.

Units
Edit inputs ↓

Live results

Vertical & horizontal foot corrections
Rear shim
-0.039076mm
Front move
0.11826mm
Rear move
0.27234mm
Rim and faceD 92 mmVerticalAdd / removeHorizontalRight / leftFront A 160 mmRear B 475 mm

Dial validity rule

Within screen
CloseError limitRecheck

Both dial sets close within tolerance. Positive moves add shims or shift right from the stationary-machine viewpoint.

Editable case inputs

Alignment geometry
mm
mm
mm
µm
First rim readings · top = 0
µm
µm
µm
Second readings · top = 0
µm
µm
µm

Use axial face readings for rim-and-face, or opposite radial readings for reverse-dial.

Cold operating target
µm
µm
µm
µm

Calculation details

Plane 1 vertical offset-0.09 mm
Plane 1 horizontal offset-0.04 mm
Vertical shaft slope0.271739 mm/m
Horizontal shaft slope-0.48913 mm/m
First rim closure error0 µm
Face closure error0 µm
Front vertical cold target0 mm
Rear vertical cold target0 mm

What to check

Check closure first, then compare front and rear corrections. The face angularity grows with distance from the coupling.

Model & assumptions

T+B = L+R · rim offset = signed TIR/2 · face slope = signed TIR/D · move = target−(offset + slope·distance)

Zero each dial at 12 o’clock and enter signed readings from the stationary-machine viewpoint looking toward the movable machine. For the first rim, positive (T−B)/2 is above and positive (L−R)/2 is right. The reverse indicator faces the opposite direction, so its radial readings have opposite polarity. For the face, (T−B)/D and (L−R)/D give slopes toward the movable machine.

Use the effective face sweep diameter or the spacing between the two rim planes. Correct for bracket sag before entry. Positive V adds shim thickness and positive H moves right. Growth mode sets the vertical cold target to stationary rise minus movable rise.

Methodology and references ↗