RotorVibLab
Menu

Measured RMS exactly on the B/C boundary

A rigid medium-size machine has an overall reading of exactly 2.8 mm/s RMS, while the selected harmonic amplitude is zero.

Units
Edit inputs ↓

Live results

Sinusoid & machine severity bands
Velocity RMS
0mm/s RMS
Accel. peak
0g pk
Velocity zone
Zone C
One sinusoidal cycle25 HzRMS velocity bandsmm/s RMSABCD1.42.84.5Measured overall2.8 mm/s RMS

ISO 20816-3 velocity bands

Review
Zone AZone BZone CZone D

Zone C uses the entered overall RMS reading.

Editable case inputs

Harmonic signal
mm/s RMS
Hz
Severity assessment
mm/s RMS

Calculation details

Tone frequency25 Hz
Tone frequency1,500 CPM
Peak velocity0 mm/s pk
RMS acceleration0 g RMS
RMS velocity used for zone2.8 mm/s RMS
A/B boundary1.4 mm/s RMS
B/C boundary2.8 mm/s RMS
C/D boundary4.5 mm/s RMS
Headroom to B/C0 mm/s RMS

What to check

The boundary is assigned to Zone C by the site convention. The zero selected harmonic converts to zero without hiding the overall reading.

Model & assumptions

xpk = xpp/2 · vpk = 2πf·xpk · apk = (2πf)²·xpk · RMS = peak/√2

Enter one sinusoidal component to convert amplitude conventions. For zone screening, choose the RMS source and enter the maximum applicable measured broadband housing velocity at steady operation. Group 2 covers power above 15 kW up to 300 kW; group 1 covers larger machines. For electric machines, verify shaft-height criteria and support stiffness in the measurement direction.

This two-group calculator uses the ISO 20816-3:2022 velocity bands for groups 1 and 2. A value exactly at a boundary is shown in the higher zone. Apply the governing edition, machinery scope and measurement bandwidth on the job.

Methodology and references ↗