RotorVibLab
Menu

Shaft Alignment Shim & Foot Move Calculator

Solve front and rear foot corrections from clocked dial readings with validity and cold-target checks.

Units
Edit inputs ↓

Live results

Vertical & horizontal foot corrections
Rear shim
-0.088mm
Front move
-0.14mm
Rear move
-0.48mm
Rim and faceD 100 mmVerticalAdd / removeHorizontalRight / leftFront A 180 mmRear B 520 mm

Dial validity rule

Within screen
CloseError limitRecheck

Both dial sets close within tolerance. Positive moves add shims or shift right from the stationary-machine viewpoint.

Operating inputs

Alignment geometry
mm
mm
mm
µm
First rim readings · top = 0
µm
µm
µm
Second readings · top = 0
µm
µm
µm

Use axial face readings for rim-and-face, or opposite radial readings for reverse-dial.

Cold operating target
µm
µm
µm
µm

Calculation details

Plane 1 vertical offset-0.12 mm
Plane 1 horizontal offset-0.04 mm
Vertical shaft slope0.4 mm/m
Horizontal shaft slope1 mm/m
First rim closure error0 µm
Face closure error0 µm
Front vertical cold target0 mm
Rear vertical cold target0 mm

Model & assumptions

T+B = L+R · rim offset = signed TIR/2 · face slope = signed TIR/D · move = target−(offset + slope·distance)

Zero each dial at 12 o’clock and enter signed readings from the stationary-machine viewpoint looking toward the movable machine. For the first rim, positive (T−B)/2 is above and positive (L−R)/2 is right. The reverse indicator faces the opposite direction, so its radial readings have opposite polarity. For the face, (T−B)/D and (L−R)/D give slopes toward the movable machine.

Use the effective face sweep diameter or the spacing between the two rim planes. Correct for bracket sag before entry. Positive V adds shim thickness and positive H moves right. Growth mode sets the vertical cold target to stationary rise minus movable rise.

Methodology and references ↗