Worked example
EAN32 Below the 0.5 ATA Oxygen Cutoff
A shallow 15 ft EAN32 example illustrates the lower boundary chosen for CNS and OTU accounting.
Inputs
Results
Live calculationFix the highlighted inputs to view the results and diagram.
- Single-dive CNS
- 0%
- Share of the NOAA single-exposure limit.
- 24-hour CNS contribution
- 0%
- Share from this segment only.
- Estimated residual CNS
- 0%
- Single-dive CNS after the entered interval.
- Oxygen tolerance units
- 0OTU
- Compared with a 300 OTU/day long-series reference.
- Oxygen partial pressure
- 0.465ATA
- NOAA calculation row
- —
- The first published row at or above the entered exposure’s PPO₂.
Work through this example
At this oxygen fraction the modeled pressure is below 0.5 ATA. The worksheet records zero by convention and shows no lookup row.
Try it. Raise the depth to 22 ft and observe the first applicable CNS row and the small OTU.
How the calculation works
Use the NOAA normal-exposure row
For 0.5 < PPO₂ ≤ 1.6 ATA, use the first published row at or above the calculated pressure. CNS percent = minutes ÷ row time × 100. The single and 24-hour columns have different time limits. CNS is zero through 0.5 ATA and unavailable above 1.6 ATA. A PPO₂ below 0.16 ATA triggers a separate hypoxia warning.
Model decay and pulmonary exposure separately
Residual CNS = single-exposure CNS × 2^(−surface minutes ÷ 90). OTU = minutes × ((PPO₂ − 0.5) ÷ 0.5)^(5/6) above 0.5 ATA. The 300 OTU/day reference is a conservative long-series comparison. Follow the exposure rules applicable to your dives.
References
More worked examples
Questions & answers
What causes zero OTU in the shallow 15 ft EAN32 example?
The equation counts exposure above 0.5 ATA. The modeled PPO₂ at 15 ft is below that threshold.
What happens just above 0.5 ATA in this CNS worksheet?
The next available NOAA row is 0.6 ATA. This implementation uses that row for a conservative estimate.