Worked example

EAN50 at 21 m and the 1.55 ATA CNS Row

An EAN50 constant-depth training example at 21 m demonstrates how the worksheet selects a published NOAA row between 1.5 and 1.6 ATA.

Inputs

%
m
min
min

Results

Live calculation
  • PPO₂ exceeds the 1.4 ATA working reference. Treat 1.6 ATA as a contingency reference only.
Single-dive CNS
18.1%
Share of the NOAA single-exposure limit.
24-hour CNS contribution
9.1%
Share from this segment only.
Estimated residual CNS
11.4%
Single-dive CNS after the entered interval.
Oxygen tolerance units
27.7OTU
Compared with a 300 OTU/day long-series reference.
Oxygen partial pressure
1.544ATA
NOAA calculation row
1.55ATA
The first published row at or above the entered exposure’s PPO₂.
CNS clock and pulmonary doseCNS 18.1%. Modeled pulmonary dose 27.7 OTU. CNS clock and pulmonary dose18.1%SINGLE CNSOXYGEN TOLERANCE UNITS27.7 OTU300 OTU/day referenceResidual after 60 min · 11.4%Depth 21 m

Work through this example

Rounding PPO₂ up selects the 1.55 ATA row. Fifteen minutes is about 18.1% of the 83-minute single limit and 9.1% of the 165-minute daily limit.

Try it. Set 22.5 m and watch the table-based outputs become unavailable as PPO₂ moves beyond 1.6 ATA.

How the calculation works

Use the NOAA normal-exposure row

For 0.5 < PPO₂ ≤ 1.6 ATA, use the first published row at or above the calculated pressure. CNS percent = minutes ÷ row time × 100. The single and 24-hour columns have different time limits. CNS is zero through 0.5 ATA and unavailable above 1.6 ATA. A PPO₂ below 0.16 ATA triggers a separate hypoxia warning.

Model decay and pulmonary exposure separately

Residual CNS = single-exposure CNS × 2^(−surface minutes ÷ 90). OTU = minutes × ((PPO₂ − 0.5) ÷ 0.5)^(5/6) above 0.5 ATA. The 300 OTU/day reference is a conservative long-series comparison. Follow the exposure rules applicable to your dives.

References

Questions & answers

Why does a 21 m EAN50 segment use the 1.55 ATA CNS row?

The pressure model yields a PPO₂ of about 1.544 ATA. The next published row is 1.55 ATA.

Why is the EAN50 single-dive percentage larger than the daily share?

The 1.55 ATA row uses 83 minutes in the single column and 165 in the 24-hour column. The same duration uses more of the shorter allowance.