Worked example
Long Oxygen Exposure Against the 300 OTU Reference
This intentionally long constant-depth input is a stress test for the display. It crosses the 300 OTU comparison line and the modeled CNS time limits.
Inputs
Results
Live calculationFix the highlighted inputs to view the results and diagram.
- This segment reaches or exceeds a modeled NOAA CNS time limit.
- This segment meets or exceeds the 300 OTU long-series comparison value.
- Single-dive CNS
- 146.7%
- Share of the NOAA single-exposure limit.
- 24-hour CNS contribution
- 122.2%
- Share from this segment only.
- Estimated residual CNS
- 58.2%
- Single-dive CNS after the entered interval.
- Oxygen tolerance units
- 357.3OTU
- Compared with a 300 OTU/day long-series reference.
- Oxygen partial pressure
- 1.395ATA
- NOAA calculation row
- 1.4ATA
- The first published row at or above the entered exposure’s PPO₂.
Work through this example
The CNS result uses NOAA time fractions and OTU uses a pressure-dependent dose formula. A segment can cross the limits at different points.
Try it. Shorten the duration to 100 minutes and compare the two exposure indicators.
How the calculation works
Use the NOAA normal-exposure row
For 0.5 < PPO₂ ≤ 1.6 ATA, use the first published row at or above the calculated pressure. CNS percent = minutes ÷ row time × 100. The single and 24-hour columns have different time limits. CNS is zero through 0.5 ATA and unavailable above 1.6 ATA. A PPO₂ below 0.16 ATA triggers a separate hypoxia warning.
Model decay and pulmonary exposure separately
Residual CNS = single-exposure CNS × 2^(−surface minutes ÷ 90). OTU = minutes × ((PPO₂ − 0.5) ÷ 0.5)^(5/6) above 0.5 ATA. The 300 OTU/day reference is a conservative long-series comparison. Follow the exposure rules applicable to your dives.
References
More worked examples
Questions & answers
Why does the 220-minute training example show two warnings?
The entered segment exceeds both a NOAA CNS time limit and the pulmonary long-series comparison line. These are different exposure measures.
Can I subtract surface interval from OTU in the long-exposure example?
OTU here is the dose from the exposure. Surface time is used only in the single-segment CNS recovery model.