How the calculation works
Read this example
Compare the roof level force with the base story shear. Only the base story shear includes the full building force.
Preset result: BASE SHEAR 210.496 kip.
From mapped hazard to the design spectrum
Interpolate Fₐ and Fᵥ using the ASCE 7-16 Supplement 3 tables. Default Site Class D uses a minimum Fₐ of 1.2. Sᴍₛ = FₐSₛ and Sᴍ₁ = FᵥS₁. Multiply each by 2/3 for the design ordinates. The design category uses the more severe result of the two SDC tables and the high-S₁ rule. Class B values assume measured rock velocity.
Strength period and governing coefficient
Tₐ = Cₜhₙˣ. The entered model period is capped by CᵤTₐ for strength. Cₛ starts at Sᴅₛ/(R/Iₑ), uses the smaller applicable upper value from Eq. 12.8-3 or 12.8-4, and then applies both lower bounds in Eqs. 12.8-5 and 12.8-6.
Level forces and shears
V = CₛW. Each level receives a share proportional to wₓhₓᵏ. k rises linearly from 1 at 0.5 s to 2 at 2.5 s. A story shear is the sum of its level force and all level forces above.
Site-specific screening and Supplement 3
For Site Class D at S₁ ≥ 0.2 g the selected exception increases Sᴍ₁ by 50%. For Site Class E at Sₛ ≥ 1.0 g or S₁ ≥ 0.2 g the selected ELF exception uses Eq. 12.8-2 for all periods, subject to the Cₛ minimums. Confirm that the exception is applicable before selecting it.
Design scope
Verify ELF eligibility, approved hazard data, system coefficients and the adopted supplement before using these loads. Site-specific ground motion analysis requires separate hazard and geotechnical data.
Source references
- ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
- ASCE 7-16 Supplement 3https://ascelibrary.org/doi/pdf/10.1061/9780784414248.sup3
- ASCE Hazard Toolhttps://www.asce.org/publications-and-news/asce-hazard-tool/
- FEMA P-1051 design exampleshttps://www.fema.gov/sites/default/files/2020-07/fema_nehrp-seismic-provisions-examples_p-1051_20160701.pdf