Worked example · ASCE 7-16 Chapter 18 · Eurocode 8 · Den Hartog

Pedestrian bridge absorber sizing

A light bridge mode uses a small candidate tuned mass ratio. The classical fixed-point peak shows the sensitivity to the added mass.

Calculation sheet
Export

Inputs

Primary oscillator
kip·s²/ft
kip/ft
%
Spectrum and absorber
g
g
s
%
PERIOD Tₙ
0.811s
FREQUENCY fₙ
1.233Hz
DAMPED Sₐ
0.493g
PSEUDO Sᴅ
3.173in

Primary frame and tuned massmmᴅk 96 kip/ftμ 2%Modified response spectrumSₐ (g)T = 0.81 s0.8008.8 s5% reference1.5% damping
The oscillator drawing identifies the primary and secondary masses. The chart compares 5% damping with the selected modifier.

Calculation detail

Modal mass
1.6 kip·s²/ft
Undamped ωₙ
7.746 rad/s
Damped ωᴅ
7.745 rad/s
5% Sₐ at Tₙ
0.394 g
Pseudo-velocity Sᵥ
2.048 ft/s
ASCE damping table B
0.8
ASCE B at Tₙ
0.8
EC8 modifier η
1.2403
TMD modal mass
0.032 kip·s²/ft
TMD frequency ratio
0.9804
TMD frequency
1.209 Hz
TMD spring stiffness
1.845 kip/ft
TMD damping ζopt
8.575%
Fixed-point peak Hmax
10.0499

How the calculation works

Read this example

Use the harmonic estimate for initial sizing. Check rhythmic loading, acceleration criteria, and device stroke in the bridge model.

Preset result: PERIOD Tₙ 0.811 s.

Calculate the primary mode

ωₙ = √(k/m), Tₙ = 2π/ωₙ, and ωᴅ = ωₙ√(1 − ζ²). With Sₐ as a fraction of g, use Sᵥ = Sₐg/ωₙ and Sᴅ = Sₐg/ωₙ² for pseudo-velocity and displacement.

Compare damping treatments

The ASCE effective damping coefficient B is interpolated from Table 18.7-1 and divides the curve by B. Below T₀, interpolate the divisor from 1 at zero period to the table value at T₀. The EC8 multiplier is max(0.55, √[10/(5 + ζ%)]), applied here to the entered two-period ASCE shape for comparison.

Tune a secondary mass

Den Hartog harmonic-force tuning uses fopt = 1/(1 + μ), kᴅ = μkfopt² and ζopt = √[3μ/(8(1 + μ))]. Hmax = √(1 + 2/μ) is the classical fixed-point estimate for the undamped primary benchmark.

Design scope

A single linear mode and a preliminary harmonic TMD estimate. The entered primary damping modifies the response spectrum and damped natural frequency. A project-specific TMD requires excitation, stroke, tolerances, and damping-system analysis.