Worked example · ASCE 7-16 Chapter 18 · Eurocode 8 · Den Hartog

Stiff oscillator near the short-period ramp

A stiff equipment mode has a very short natural period and a low damping ratio. The short-period spectral ramp controls its demand.

Calculation sheet
Export

Inputs

Primary oscillator
kip·s²/ft
kip/ft
%
Spectrum and absorber
g
g
s
%
PERIOD Tₙ
0.043s
FREQUENCY fₙ
23.168Hz
DAMPED Sₐ
0.535g
PSEUDO Sᴅ
0.01in

Primary frame and tuned massmmᴅk 8,900 kip/ftμ 8%Modified response spectrumSₐ (g)T = 0.04 s1.03008.8 s5% reference2.5% damping
The oscillator drawing identifies the primary and secondary masses. The chart compares 5% damping with the selected modifier.

Calculation detail

Modal mass
0.42 kip·s²/ft
Undamped ωₙ
145.569 rad/s
Damped ωᴅ
145.524 rad/s
5% Sₐ at Tₙ
0.5 g
Pseudo-velocity Sᵥ
0.118 ft/s
ASCE damping table B
0.833
ASCE B at Tₙ
0.933
EC8 modifier η
1.1547
TMD modal mass
0.034 kip·s²/ft
TMD frequency ratio
0.9259
TMD frequency
21.452 Hz
TMD spring stiffness
610.425 kip/ft
TMD damping ζopt
16.667%
Fixed-point peak Hmax
5.099

How the calculation works

Read this example

The two curves share the zero-period intercept. They separate as the period approaches T₀.

Preset result: PERIOD Tₙ 0.043 s.

Calculate the primary mode

ωₙ = √(k/m), Tₙ = 2π/ωₙ, and ωᴅ = ωₙ√(1 − ζ²). With Sₐ as a fraction of g, use Sᵥ = Sₐg/ωₙ and Sᴅ = Sₐg/ωₙ² for pseudo-velocity and displacement.

Compare damping treatments

The ASCE effective damping coefficient B is interpolated from Table 18.7-1 and divides the curve by B. Below T₀, interpolate the divisor from 1 at zero period to the table value at T₀. The EC8 multiplier is max(0.55, √[10/(5 + ζ%)]), applied here to the entered two-period ASCE shape for comparison.

Tune a secondary mass

Den Hartog harmonic-force tuning uses fopt = 1/(1 + μ), kᴅ = μkfopt² and ζopt = √[3μ/(8(1 + μ))]. Hmax = √(1 + 2/μ) is the classical fixed-point estimate for the undamped primary benchmark.

Design scope

A single linear mode and a preliminary harmonic TMD estimate. The entered primary damping modifies the response spectrum and damped natural frequency. A project-specific TMD requires excitation, stroke, tolerances, and damping-system analysis.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • JRC Eurocode 8 worked exampleshttps://eurocodes.jrc.ec.europa.eu/sites/default/files/2022-06/EC8_Seismic_Design_of_Buildings-Worked_examples-main_only.pdf
  • Marian and Giaralis, classical TMD comparisonhttps://openaccess.city.ac.uk/id/eprint/17700/7/Marian%20and%20Giaralis_SSS_revised%20paper_ACCEPTED.pdf

More sdof spectrum & tuned mass examples