Worked example · ASCE/SEI 7-16 §12.8.4, Table 12.3-1

Six-wall mixed-use podium

Two interior wall lines supplement four perimeter walls. The added lines redistribute translation and rotation according to their individual stiffness and distance to CR.

Calculation sheet
Export

Inputs

Diaphragm and center of mass
ft
ft
ft
ft
Story loading
kip
kip
Editable wall schedule

Use coordinates from the lower-left plan corner. An X wall resists X translation and a Y wall resists Y translation.

Wall 1
kip/ft
ft
ft
Wall 2
kip/ft
ft
ft
Wall 3
kip/ft
ft
ft
Wall 4
kip/ft
ft
ft
Wall 5
kip/ft
ft
ft
Wall 6
kip/ft
ft
ft
RIGIDITY X
66.355ft
RIGIDITY Y
44.453ft
EDGE RATIO
1.2639
MAX WALL
98.348kip
Irregular torsion screen

Compare the independent X and Y edge ratios. The signed combined cases preserve force equilibrium. The no-relief column adds peak torsional magnitude to direct magnitude.

Wall plan and eccentricityCRCMX wallY walleₓ 4.64 fteᵧ -0.45 ftWall shear envelopeX · 198.35 kipX · 295.65 kipY · 369.76 kipY · 465.04 kipX · 576.92 kipY · 642.02 kipSigned envelopeNo-relief magnitude
The plan places both centers and all active wall lines. The bars compare signed-case envelopes with no-relief demand.

Calculation detail

Total X stiffness
128 kip/ft
Total Y stiffness
152 kip/ft
Rotational stiffness J
378,090.535 kip·ft/rad
CM − CR in X
4.645 ft
CM − CR in Y
-0.453 ft
Accidental offset X (±)
6 ft
Accidental offset Y (±)
4 ft
Inherent torque
740.321 kip·ft
Peak |torque|
2,550.321 kip·ft
Wall shear — signed cases and magnitudes
WallDirect (kip)+X/+Y (kip)+X/−Y (kip)−X/+Y (kip)−X/−Y (kip)Envelope (kip)No relief (kip)
X · 187.890690.147398.348483.504391.705598.348498.3484
X · 287.890686.217380.136291.143185.061991.143195.645
Y · 348.848744.337227.941557.617841.22257.617869.7559
Y · 448.848752.342665.040442.057454.755265.040465.0404
X · 574.218873.635471.515475.352673.232675.352676.9221
Y · 637.302638.320242.018135.324839.022842.018142.0181
Extreme edge drifts — independent axis checks
Load caseNear edge (in)Far edge (in)Max / avg
X −5%25.008222.18151.0599
X +5%22.186524.43791.0483
Y −5%11.043210.34641.0326
Y +5%7.631513.10461.2639

How the calculation works

Read this example

Change an interior coordinate and confirm the contribution to J changes with the square of its transverse distance.

Preset result: RIGIDITY X 66.355 ft.

Compute the stiffness center

X rigidity is the stiffness-weighted X coordinate of Y walls. Y rigidity uses Y coordinates of X walls. J sums each wall stiffness times the square of its transverse arm to CR.

Keep signed and conservative cases visible

Combined torque is Vᵧeₓ − Vₓeᵧ. Add independent ±5% offsets in both axes. Each signed case adds the torsional force from its own rotation to the direct share. The no-relief magnitude adds the largest absolute torsional contribution to the absolute direct share.

Screen each axis for irregularity

Each active axis has two independent ±5% checks. The ratio divides the larger absolute edge displacement by the average of the two absolute values. Above 1.2 is torsionally irregular and above 1.4 is extreme.

Design scope

One-story elastic rigid-diaphragm model using orthogonal translational springs. The screen uses accidental torsion at Aₓ = 1. Check code applicability, amplification Aₓ, actual relative story drifts, load combinations, and the orthogonal load rule in the full structure.

Source references
  • ASCE/SEI 7-16 standardhttps://ascelibrary.org/doi/book/10.1061/9780784414248
  • FEMA P-1051 design exampleshttps://www.fema.gov/sites/default/files/2020-07/fema_nehrp-seismic-provisions-examples_p-1051_20160701.pdf

More shear-wall torsion examples