One-hour RPO for a small edge database
An edge database holds 45 GB and changes by 20% each day. The team needs hourly points for seven days and duplicates selected fulls to longer tiers.
Jump to resultsInputs
Results
Runs in your browser- Stored archive
- 159.792GB
- Worst-chain restore
- 3.136h
- Modeled recovery interval
- 1h
The modeled restore and recovery interval meet the supplied targets. Confirm with an exercise.
| Daily tier | 59.792 GB |
|---|---|
| Weekly tier | 50 GB |
| Monthly tier | 50 GB |
| Yearly tier | 0 GB |
| Incrementals in worst chain | 167 |
| Retained recovery points | 172 |
| Effective reduction vs all fulls | 48.438 × |
| Worst restore bytes on wire | 71.75 GB |
| Transfer time only | 2.886 h |
What to try
An hourly schedule narrows the data loss window but creates many incremental segments. Use a restore exercise to measure overhead per incremental and test an interrupted edge link.
How the estimate works
RTO ≈ restore preparation + bytes on wire ÷ usable restore bandwidth
The daily tier starts with one full backup followed by incrementals. Weekly, monthly, and yearly checkpoints are separate full restore points. The model assumes distinct checkpoints, steady changes, and deduplication plus compression across stored data.
The worst daily-chain restore reads a full backup and all retained incrementals. Archive dedup by itself does not reduce the logical bytes a full restore needs. The wire estimate assumes compressed transfer and uses the configured link efficiency plus preparation and replay time.
The modeled recovery point interval uses the daily-tier backup schedule when enabled, or the most frequent retained full tier otherwise. Measure actual backup delays and restore throughput to validate your recovery objectives.
Frequently asked questions
Does a one-hour edge schedule mean each incremental changes 20%?
The input is daily change. This model spreads 20% evenly over 24 hourly increments, though real updates can arrive in spikes.
Can offline edge sites safely report a one-hour remote recovery interval?
Measure which points reached the remote repository. A locally completed backup does not guarantee that another site can restore it.