One-hour RPO for a small edge database

An edge database holds 45 GB and changes by 20% each day. The team needs hourly points for seven days and duplicates selected fulls to longer tiers.

Jump to results

Inputs

Protected data
GB
%
×
×
GFS retention
Recovery targets and link
Mbps
%
hours
hours
hours

Results

Runs in your browser
Stored archive
159.792GB
Worst-chain restore
3.136h
Modeled recovery interval
1h

The modeled restore and recovery interval meet the supplied targets. Confirm with an exercise.

Retention tiers and restore time
Retention tiers and restore timeStored archive 159.792 GB. Worst-chain restore 3.136 h. Modeled recovery interval 1 hStored archive159.792 GBDailyWeeklyMonthlyYearlyWorst restore vs target3.136 h / 4 hPreparationTransferRTO target
Detailed results
Daily tier59.792 GB
Weekly tier50 GB
Monthly tier50 GB
Yearly tier0 GB
Incrementals in worst chain167
Retained recovery points172
Effective reduction vs all fulls48.438 ×
Worst restore bytes on wire71.75 GB
Transfer time only2.886 h

What to try

An hourly schedule narrows the data loss window but creates many incremental segments. Use a restore exercise to measure overhead per incremental and test an interrupted edge link.

How the estimate works

RTO ≈ restore preparation + bytes on wire ÷ usable restore bandwidth

The daily tier starts with one full backup followed by incrementals. Weekly, monthly, and yearly checkpoints are separate full restore points. The model assumes distinct checkpoints, steady changes, and deduplication plus compression across stored data.

The worst daily-chain restore reads a full backup and all retained incrementals. Archive dedup by itself does not reduce the logical bytes a full restore needs. The wire estimate assumes compressed transfer and uses the configured link efficiency plus preparation and replay time.

The modeled recovery point interval uses the daily-tier backup schedule when enabled, or the most frequent retained full tier otherwise. Measure actual backup delays and restore throughput to validate your recovery objectives.

Frequently asked questions

Does a one-hour edge schedule mean each incremental changes 20%?

The input is daily change. This model spreads 20% evenly over 24 hourly increments, though real updates can arrive in spikes.

Can offline edge sites safely report a one-hour remote recovery interval?

Measure which points reached the remote repository. A locally completed backup does not guarantee that another site can restore it.

Open Backup retention & restores calculator