Disaster recovery over a constrained WAN
A regional failover needs to recover 18 TB of protected data. The 2.5 Gbps WAN reserves only 60% of nominal bandwidth for recovery traffic.
Jump to resultsInputs
Results
Runs in your browser- Stored archive
- 49.44TB
- Worst-chain restore
- 30.056h
- Modeled recovery interval
- 24h
The modeled plan exceeds at least one recovery target. Compare the restore and recovery interval separately.
| Daily tier | 7.44 TB |
|---|---|
| Weekly tier | 24 TB |
| Monthly tier | 18 TB |
| Yearly tier | 0 GB |
| Incrementals in worst chain | 6 |
| Retained recovery points | 14 |
| Effective reduction vs all fulls | 5.097 × |
| Worst restore bytes on wire | 18.6 TB |
| Transfer time only | 27.556 h |
What to try
The calculated RTO is about 30 hours, beyond the 24-hour target. Compare staged restore scope, pre-positioned data, and more usable link bandwidth before changing retention.
How the estimate works
RTO ≈ restore preparation + bytes on wire ÷ usable restore bandwidth
The daily tier starts with one full backup followed by incrementals. Weekly, monthly, and yearly checkpoints are separate full restore points. The model assumes distinct checkpoints, steady changes, and deduplication plus compression across stored data.
The worst daily-chain restore reads a full backup and all retained incrementals. Archive dedup by itself does not reduce the logical bytes a full restore needs. The wire estimate assumes compressed transfer and uses the configured link efficiency plus preparation and replay time.
The modeled recovery point interval uses the daily-tier backup schedule when enabled, or the most frequent retained full tier otherwise. Measure actual backup delays and restore throughput to validate your recovery objectives.
Frequently asked questions
Why is a 2.5 Gbps WAN budgeted at only 1.5 Gbps during recovery?
This scenario assigns 60% to restore traffic. Maintenance, contention, and other recovery workloads can consume the rest.
Will doubling WAN capacity always halve this disaster recovery time?
It halves the modeled transfer component at unchanged efficiency. Fixed preparation and replay time still applies, and storage may become the limiting stage.