Disaster recovery over a constrained WAN

A regional failover needs to recover 18 TB of protected data. The 2.5 Gbps WAN reserves only 60% of nominal bandwidth for recovery traffic.

Jump to results

Inputs

Protected data
GB
%
×
×
GFS retention
Recovery targets and link
Mbps
%
hours
hours
hours

Results

Runs in your browser
Stored archive
49.44TB
Worst-chain restore
30.056h
Modeled recovery interval
24h

The modeled plan exceeds at least one recovery target. Compare the restore and recovery interval separately.

Retention tiers and restore time
Retention tiers and restore timeStored archive 49.44 TB. Worst-chain restore 30.056 h. Modeled recovery interval 24 hStored archive49.44 TBDailyWeeklyMonthlyYearlyWorst restore vs target30.056 h / 24 hPreparationTransferRTO target
Detailed results
Daily tier7.44 TB
Weekly tier24 TB
Monthly tier18 TB
Yearly tier0 GB
Incrementals in worst chain6
Retained recovery points14
Effective reduction vs all fulls5.097 ×
Worst restore bytes on wire18.6 TB
Transfer time only27.556 h

What to try

The calculated RTO is about 30 hours, beyond the 24-hour target. Compare staged restore scope, pre-positioned data, and more usable link bandwidth before changing retention.

How the estimate works

RTO ≈ restore preparation + bytes on wire ÷ usable restore bandwidth

The daily tier starts with one full backup followed by incrementals. Weekly, monthly, and yearly checkpoints are separate full restore points. The model assumes distinct checkpoints, steady changes, and deduplication plus compression across stored data.

The worst daily-chain restore reads a full backup and all retained incrementals. Archive dedup by itself does not reduce the logical bytes a full restore needs. The wire estimate assumes compressed transfer and uses the configured link efficiency plus preparation and replay time.

The modeled recovery point interval uses the daily-tier backup schedule when enabled, or the most frequent retained full tier otherwise. Measure actual backup delays and restore throughput to validate your recovery objectives.

Frequently asked questions

Why is a 2.5 Gbps WAN budgeted at only 1.5 Gbps during recovery?

This scenario assigns 60% to restore traffic. Maintenance, contention, and other recovery workloads can consume the rest.

Will doubling WAN capacity always halve this disaster recovery time?

It halves the modeled transfer component at unchanged efficiency. Fixed preparation and replay time still applies, and storage may become the limiting stage.

Open Backup retention & restores calculator