Login service with a 480-request budget

A login service measures 4.8 million eligible authentication attempts every 28 days. It recorded 384 platform failures against an availability target of 99.99%.

Jump to results

Inputs

Service objective
%
Burn-rate observations

Use the same availability indicator for each interval. Blank observations leave the corresponding alert unassessed.

% errors
% errors
% errors
% errors
% errors

Results

Runs in your browser
Remaining budget
96requests
Allowed failures
480requests
Time to exhaustion
3,360min At the recent measured rate

The exhaustion estimate uses the last five minutes of errors.

Budget and burn rates
Budget and burn rates80 percent used. 96 requests remains.Error budget used80%480 requests allowed in this windowShort / long windows relative to alert threshold1 h / 5 min14.4× · Below6 h / 30 min6× · Below3 days / 6 h1× · BelowLong windowShort windowThreshold
Detailed results
Observed uptime99.992 %
Budget used80 %
Current burn rate2.4 ×
Reporting window burn0.8 ×
1 h burn at 14.4× threshold4 ×
5 min burn for 1 h / 5 min2.4 ×
Page for 1 h / 5 minBelow threshold
6 h burn at 6× threshold5.5 ×
30 min burn for 6 h / 30 min3.5 ×
Page for 6 h / 30 minBelow threshold
3 days burn at 1× threshold0.9 ×
6 h burn for 3 days / 6 h5.5 ×
Ticket for 3 days / 6 hBelow threshold

What to try

There are 96 eligible failures left at this traffic level. Change the total to your forecast after removing client retries or tests, and check whether the same 384 failures are still within target.

How the estimate works

Error budget = (1 − SLO) × window size

A time-based budget is the outage allowance over the full reporting window. A request-based budget is the maximum whole number of eligible requests that can fail while meeting the objective.

Burn rate is the observed error rate divided by the allowed error rate. Each alert requires both windows to meet the threshold. The same 14.4×, 6×, and 1× thresholds are offered for all windows. Their budget fractions were originally set for a 30-day SLO.

Time to exhaustion projects the last five minutes of burn, or uses your full-window average when that reading is blank. For request-based objectives it assumes the reporting window’s average request volume continues.

Frequently asked questions

Does a mistyped password use up the login availability budget?

An application that correctly returns an invalid-credentials response fulfilled its availability promise. Count authentication infrastructure failures that block a valid attempt.

How do traffic spikes affect a login failure budget?

More eligible requests increase the whole-request allowance. Use a daily or rolling view alongside the monthly view so a high-volume day cannot bury issues during a quiet interval.