Low-solids feedwater sensitivity

A boiler receives low-solids feedwater and returns 80% of produced steam as condensate. Evaluate the continuous TDS-driven discharge.

Inputs

lb/hr
psig
ppm
%
°F
psig
%
%
%
h/yr
Currency labels your tariff and savings. Enter local prices.
USD/MMBtu
Drum solids and heat-recovery balance
Drum solids and heat-recovery balanceBLOWDOWN 0.57 %. CYCLES 175 ×. BD FLOW 51.7 lb/hr. FUEL SAVINGS 723 USD/yrBLOWDOWN0.57%CYCLES175×BD FLOW51.7lb/hrFUEL SAVINGS723USD/yrBOILER DRUM3,500 ppm targetFEEDWATER20 ppm inLIVE STEAMFLASH + HX60.03% recoveredBLOWDOWNRecovered / gross blowdown heat60.03%0%Annual sensible and latent heat100%
Live steam / heatCondensate / waterDischarge / loss

Calculation results

Blowdown / steam production
0.57%
Blowdown flow
51.7lb/hr
TDS cycles of concentration
175×
Fresh make-up flow
1,851.7lb/hr
Total boiler feedwater
9,051.7lb/hr
Effective feedwater TDS
20ppm
Drum TDS target
3,500ppm
ABMA screening value
3,500ppm
Gross annual blowdown heat
116.2MMBtu/yr
Generated flash steam with recovery
10lb/hr
Usable flash heat
6,742.7Btu/h
Liquid HX heat
3,985.34Btu/h
Annual heat recovered
69.7MMBtu/yr
Annual unrecovered heat
46.4MMBtu/yr
Annual fuel energy avoided
85MMBtu/yr
Annual fuel savings
723USD/yr

Check the original case

Try zero feed TDS to see the theoretical solids balance. Site chemistry and OEM guidance govern actual operation.

  • Blowdown / steam production0.57 %
  • TDS cycles of concentration175 ×
  • Blowdown flow51.7 lb/hr
  • Annual fuel savings723 USD/yr

Formulas and assumptions

Steady drum solids

BD/S = F/(B − F); cycles = B/F

F is the effective feedwater TDS, B is the drum target and S is dry steam production. Conductivity is multiplied by an editable site factor. Zero feed TDS gives zero calculated continuous blowdown and unlimited theoretical cycles.

Water balance and screening bands

Feed = S + BD; make-up = feed − returned condensate

ABMA screening values are 3,500 ppm through 300 psig, 3,000 ppm above 300 through 450 psig, and 2,500 ppm above 450 through 600 psig. Use the verified OEM or site target when it is more restrictive.

Flash and heat exchanger

f = (h_f,boiler − h_f,receiver)/h_fg,receiver; Q_BD = BD·(h_f,boiler − h_makeup)

Usable vapor yields flash latent heat. The exchanger recovers an entered fraction of the remaining liquid sensible heat relative to make-up. Divide recovered heat by boiler efficiency to estimate fuel avoided.

Worked examples

Open a case to edit its inputs.